140PC...-PCB Series  
Signal conditioned precision pressure transducers  
PERFORMANCE CHARACTERISTICS  
(unless otherwise noted VS = 8.00 ±0.01 V, RL > 100 k, tamb = 25°C)  
Characteristics  
Operating pressure  
Min.  
Typ.  
Max.  
Unit  
vacuum gage devices2  
differential devices3  
141PC01G-PCB  
141PC05G-PCB  
141PC15G-PCB  
141PC30G-PCB  
141PC100G-PCB  
142PC01D-PCB  
142PC05D-PCB  
142PC15D-PCB  
142PC30D-PCB  
142PC100D-PCB  
142PC150D-PCB  
142PC15A-PCB  
142PC30A-PCB  
142PC100A-PCB  
143PC01D-PCB  
143PC03D-PCB  
143PC05D-PCB  
143PC15D-PCB  
-1  
-5  
0
0
0
0
0
psig  
-15  
-30  
-100  
(vacuum)  
0
0
0
0
0
0
0
0
0
1
5
15  
30  
100  
150  
psid(g)  
absolute devices3  
15  
30  
psia  
100  
pressure/vacuum devices3  
-1  
-2.5  
-5  
1
2.5  
5
psid(g)  
-15  
15  
Zero pressure offset  
141PC.../142PC...-PCB  
0.95  
1.00  
3.50  
1.05  
143PC...-PCB  
3.45  
3.55  
Full scale span4  
141PC.../142PC...-PCB  
143PC...-PCB  
4.95  
2.45  
5.00  
5.05  
2.55  
V
2.50  
Full scale output  
5.90  
6.00  
1.00  
0.1  
6.10  
Output at lowest specified pressure  
143PC...-PCB  
Non-linearity and hysteresis (BSL)5  
0.5  
±3.0  
±1.0  
Thermal effects6  
all 1 psi devices  
all others  
±1.5  
%FSO  
Combined offset and span (0 to 70°C)  
±0.5  
Long term stability7  
±0.1  
0.1  
4.5  
Response time (10 to 90%)  
Current consumption  
ms  
mA  
Radiated, radio frequency electromagnetic  
field immunity (RFI) EN6100-4-3 grade 3,  
80 to 1000 MHz,  
10  
V/m  
80 % AMC (1 KHz)  
Specification notes:  
Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element.  
The output signal of all 141PC...-PCB devices is proportional to the vacuum applied to port A, relative to port B, e. g. the  
output signal increases when pressure is applied to port B relative to port A.  
1.  
2.  
The output signal of all 142PC...D-PCB and 143PC...D-PCB devices is proportional to the pressure applied to portA, relative  
to port B, e.g. the output signal increases when vacuum is applied to port B relative to port A.  
3.  
Full scale span is the algebraic difference between the positive full scale output and the zero pressure offset.  
Non-linearity refers to the Best Straight Line fit measured for offset pressure, full scale pressure and 1/2 full scale pressure.  
Thermal effects tested and guaranteed from 0 - 70°C relative to 25°C. All specifications shown are relative to 25°C.  
Change in output after one year or 1 million pressure cycles.  