E0C6S32
E0C6SL32 (Heavy Load Protection Mode)
(Unless otherwise specified: VDD=0V, VSS=-1.5V, fOSC1=32.768kHz, Ta=25°C, CG=25pF, VS1/VL1–VL3 are internal voltage, C1–C5=0.1µF)
Characteristic
Internal voltage
Symbol
VL1
Condition
Connect 1MΩ load resistor between VDD and VL1
(without panel load)
Min.
-1.15
Typ.
-1.05
Max.
-0.95
Unit
V
VL2
VL3
Connect 1MΩ load resistor between VDD and VL2
(without panel load)
Connect 1MΩ load resistor between VDD and VL3
(without panel load)
2•VL1
-0.1
3•VL1
-0.1
2•VL1
×0.85
3•VL1
×0.85
-1.10
V
V
SVD voltage
VSVD
tSVD
VIP
-1.30
-1.20
V
µS
V
SVD circuit response time
Analog comparator
input voltage
100
VDD-0.9
Noninverted input (AMPP)
Inverted input (AMPM)
VSS+0.3
VIM
Analog comparator
offset voltage
Analog comparator
response time
VOF
20
3
mV
mS
tAMP
IOP
VIP=-1.1V, VIM=VIP±30mV
During HALT *1
Current consumption
11.2
14.5
34.0
40.0
µA
µA
Without panel load
During operation *1
1: The SVD circuit is in the ON status (HLMOD="1", BLS="0"). The analog comparator is in the OFF status.
E0C6SB32 (Normal Mode)
(Unless otherwise specified: VDD=0V, VSS=-1.5V, fOSC1=32.768kHz, Ta=25°C, CG=25pF, VS1/VL1–VL3 are internal voltage, C1–C5=0.1µF)
Characteristic
Internal voltage
Symbol
VL1
Condition
Connect 1MΩ load resistor between VDD and VL1
(without panel load)
Min.
-1.15
Typ.
-1.05
Max.
-0.95
Unit
V
VL2
VL3
Connect 1MΩ load resistor between VDD and VL2
(without panel load)
Connect 1MΩ load resistor between VDD and VL3
(without panel load)
2•VL1
-0.1
3•VL1
-0.1
2•VL1
×0.9
3•VL1
×0.9
V
V
SVD voltage
VSVD
tSVD
VIP
-1.30
-1.20
-1.10
100
VDD-0.9
V
µS
V
SVD circuit response time
Analog comparator
input voltage
Noninverted input (AMPP)
Inverted input (AMPM)
VSS+0.3
VIM
Analog comparator
offset voltage
Analog comparator
response time
VOF
20
3
mV
mS
tAMP
IOP
VIP=-1.1V, VIM=VIP±30mV
Current consumption
During HALT
During operation *1
0.65
2.0
1.5
4.0
µA
µA
Without panel load
1: The SVD circuit and analog comparator are in the OFF status.
E0C6SB32 (Heavy Load Protection Mode)
(Unless otherwise specified: VDD=0V, VSS=-1.5V, fOSC1=32.768kHz, Ta=25°C, CG=25pF, VS1/VL1–VL3 are internal voltage, C1–C5=0.1µF)
Characteristic
Internal voltage
Symbol
Condition
Min.
-1.15
Typ.
-1.05
Max.
-0.95
Unit
V
V
V
V
V
L1
Connect 1MΩ load resistor between VDD and VL1
(without panel load)
Connect 1MΩ load resistor between VDD and VL2
(without panel load)
Connect 1MΩ load resistor between VDD and VL3
(without panel load)
L2
2•VL1
-0.1
3•VL1
-0.1
2•VL1
×0.85
3•VL1
×0.85
-1.10
100
V
V
L3
SVD voltage
SVD
-1.30
-1.20
V
µS
V
SVD circuit response time
Analog comparator
input voltage
Analog comparator
offset voltage
t
SVD
V
V
V
IP
Noninverted input (AMPP)
Inverted input (AMPM)
V
SS+0.3
V
DD-0.9
IM
OF
20
mV
mS
Analog comparator
response time
t
AMP
V
IP=-1.1V, VIM=VIP±30mV
3
Current consumption
I
OP
During HALT *1
During operation *1
11.2
14.5
34.0
40.0
µA
µA
Without panel load
1: The SVD circuit is in the ON status (HLMOD="1", BLS="0"). The analog comparator is in the OFF status.