E0C6S27
E0C6SA27 (CR, Normal Operating Mode)
(Unless otherwise specified: VDD=0V, VSS=-3.0V, fOSC=200kHz, RCR=160kΩ, Ta=25°C, VS1/VL1–VL3 are internal voltage, C1–C5=0.1µF)
Characteristic
Internal voltage
Symbol
Condition
Connect 1MΩ load resistor between VDD and VL1
(without panel load)
Connect 1MΩ load resistor between VDD and VL2
(without panel load)
Min.
Typ.
-2.10
-2.40
Max.
Unit
V
V
V
V
L1
1
1
2
—•VL2-0.1
2
—•VL2×0.9
V
L2
-2.25
-1.95
V
V
L3
Connect 1MΩ load resistor between VDD and VL3
(without panel load)
3
2
3
2
—•VL2-0.1
—•VL2×0.9
SVD voltage
SVD circuit response time
Current consumption
SVD
-2.55
-2.25
100
110
130
V
t
SVD
µS
µA
µA
I
OP
During HALT
During execution *1
60
70
Without panel load
1: The SVD circuit is turned off.
E0C6SA27 (CR, Heavy Load Protection Mode)
(Unless otherwise specified: VDD=0V, VSS=-3.0V, fOSC=200kHz, RCR=160kΩ, Ta=25°C, VS1/VL1–VL3 are internal voltage, C1–C5=0.1µF)
Characteristic
Internal voltage
Symbol
Condition
Connect 1MΩ load resistor between VDD and VL1
(without panel load)
Connect 1MΩ load resistor between VDD and VL2
(without panel load)
Min.
Typ.
-2.10
-2.40
Max.
Unit
V
V
V
V
L1
1
1
2
—•VL2-0.1
2
—•VL2×0.85
V
L2
-2.25
-1.95
V
V
L3
Connect 1MΩ load resistor between VDD and VL3
(without panel load)
3
2
3
2
—•VL2-0.1
—•VL2×0.85
SVD voltage
SVD circuit response time
Current consumption
SVD
-2.55
-2.25
100
160
180
V
t
SVD
µS
µA
µA
I
OP
During HALT
During execution *1
85
95
Without panel load
1: The SVD circuit is turned off.
E0C6SB27 (CR, Normal Operating Mode)
(Unless otherwise specified: VDD=0V, VSS=-3.0V, fOSC=65kHz, RCR=470kΩ, Ta=25°C, VS1/VL1–VL3 are internal voltage, C1–C5=0.1µF)
Characteristic
Internal voltage
Symbol
Condition
Connect 1MΩ load resistor between VDD and VL1
(without panel load)
Connect 1MΩ load resistor between VDD and VL2
(without panel load)
Min.
Typ.
Max.
Unit
V
V
V
V
L1
-1.15
-1.05
-0.95
V
L2
2•VL1-0.1
2•VL1×0.9
3•VL1×0.9
V
V
L3
Connect 1MΩ load resistor between VDD and VL3
(without panel load)
3•VL1-0.1
-1.30
SVD voltage
SVD circuit response time
Current consumption
SVD
-1.20
-1.10
100
14.0
18.0
V
t
SVD
µS
µA
µA
I
OP
During HALT
During execution *1
6.5
9.0
Without panel load
1: The SVD circuit is turned off.
E0C6SB27 (CR, Heavy Load Protection Mode)
(Unless otherwise specified: VDD=0V, VSS=-3.0V, fOSC=65kHz, RCR=470kΩ, Ta=25°C, VS1/VL1–VL3 are internal voltage, C1–C5=0.1µF)
Characteristic
Internal voltage
Symbol
Condition
Connect 1MΩ load resistor between VDD and VL1
(without panel load)
Connect 1MΩ load resistor between VDD and VL2
(without panel load)
Min.
Typ.
Max.
Unit
V
V
V
V
L1
-1.15
-1.05
-0.95
V
L2
2•VL1-0.1
2•VL1×0.85
3•VL1×0.85
V
V
L3
Connect 1MΩ load resistor between VDD and VL3
(without panel load)
3•VL1-0.1
-1.30
SVD voltage
SVD circuit response time
Current consumption
SVD
-1.20
-1.10
100
35.0
40.0
V
t
SVD
µS
µA
µA
I
OP
During HALT
During execution *1
15.0
18.0
Without panel load
1: The SVD circuit is turned off.
8