E0C6005
E0C6005 (CR, Normal Operating Mode)
(Unless otherwise specified: VDD=0V, VSS=-3.0V, fOSC=65kHz, Ta=25°C, C
G
=25pF, VS1/VL1–VL3 are internal voltage, C1=C2=0.1µF
Recommended external resistance for CR oscillation=420kΩ <During A/D conversion: RS=49.8kΩ, TH=50kΩ, CAD=2,200pF>)
Characteristic
Internal voltage
Symbol
Condition
Connect 1MΩ load resistor between VDD and VL1
(without panel load)
Connect 1MΩ load resistor between VDD and VL2
(without panel load)
Min.
1/2•VL2
-0.1
Typ.
Max.
1/2•VL2
×0.9
Unit
V
VL1
VL2
VL3
VSS
V
V
Connect 1MΩ load resistor between VDD and VL3
(without panel load)
3/2•VL2
-0.1
3/2•VL2
×0.9
Power current consumption
I
OP
During HALT
During execution
During A/D conversion (HALT)
8.0
15.0
37
15.0
20.0
52.5
µA
µA
µA
Without panel load
E0C6005 (CR, Heavy Load Protection Mode)
(Unless otherwise specified: VDD=0V, VSS=-3.0V, fOSC=65kHz, Ta=25°C, C
G
=25pF, VS1/VL1–VL3 are internal voltage, C1=C2=0.1µF
Recommended external resistance for CR oscillation=420kΩ <During A/D conversion: RS=49.8kΩ, TH=50kΩ, CAD=2,200pF>)
Characteristic
Internal voltage
Symbol
Condition
Connect 1MΩ load resistor between VDD and VL1
(without panel load)
Connect 1MΩ load resistor between VDD and VL2
(without panel load)
Connect 1MΩ load resistor between VDD and VL3
(without panel load)
During HALT
Min.
1/2•VL2
-0.1
Typ.
Max.
1/2•VL2
×0.85
Unit
V
VL1
VL2
VL3
V
SS
V
V
3/2•VL2
-0.1
3/2•VL2
×0.85
30.0
40.0
57.5
Power current consumption
I
OP
16.0
30.0
45
µA
µA
µA
During execution
Without panel load
During A/D conversion (HALT)
E0C60L05 (CR, Normal Operating Mode)
(Unless otherwise specified: VDD=0V, VSS=-1.5V, fOSC=65kHz, Ta=25°C, C
G
=25pF, VS1/VL1–VL3 are internal voltage, C1=C2=0.1µF
Recommended external resistance for CR oscillation=420kΩ <During A/D conversion: RS=49.8kΩ, TH=50kΩ, CAD=2,200pF>)
Characteristic
Internal voltage
Symbol
Condition
Connect 1MΩ load resistor between VDD and VL1
(without panel load)
Connect 1MΩ load resistor between VDD and VL2
(without panel load)
Connect 1MΩ load resistor between VDD and VL3
(without panel load)
During HALT
Min.
Typ.
VSS
Max.
Unit
V
VL1
VL2
VL3
2•VL1
-0.1
3•VL1
-0.1
2•VL1
×0.9
3•VL1
×0.9
15.0
20.0
52.5
V
V
Power current consumption
I
OP
8.0
15.0
37
µA
µA
µA
During execution
Without panel load
During A/D conversion (HALT)
E0C60L05 (CR, Heavy Load Protection Mode)
(Unless otherwise specified: VDD=0V, VSS=-1.5V, fOSC=65kHz, Ta=25°C, C
G
=25pF, VS1/VL1–VL3 are internal voltage, C1=C2=0.1µF
Recommended external resistance for CR oscillation=420kΩ <During A/D conversion: RS=49.8kΩ, TH=50kΩ, CAD=2,200pF>)
Characteristic
Internal voltage
Symbol
Condition
Connect 1MΩ load resistor between VDD and VL1
(without panel load)
Connect 1MΩ load resistor between VDD and VL2
(without panel load)
Connect 1MΩ load resistor between VDD and VL3
(without panel load)
During HALT
Min.
Typ.
VSS
Max.
Unit
V
VL1
VL2
VL3
2•VL1
-0.1
3•VL1
-0.1
2•VL1
×0.85
3•VL1
×0.85
30.0
V
V
Power current consumption
I
OP
16.0
30.0
45
µA
µA
µA
During execution
40.0
57.5
Without panel load
During A/D conversion (HALT)
7