SS732
Hall Latch - High Sensitivity
General Electrical Specifications
DC Operating Parameters TA = 25°C, VDD= 3.5V to 24V (unless otherwise specified)
Typ
Parameter
Symbol Test Conditions
Min
Max
24
Units
V
VDD
IDD
Supply Voltage
Operating
3.5
B <
BRP
Supply Current
5
mA
V
VDSon
IOFF
Tr
IOUT = 20mA, B >
Output Saturation Voltage
Output Leakage Current
Output Rise Time
0.5
10
BOP
B <
VOUT = 24V
1
BRP
µA
µs
0.25
0.25
12
RL = 1kΩ, CL = 20pF
T
f
Output Fall Time
RL = 1kΩ, CL = 20pF
µs
Internal pull-up resistor
---
---
9
15
Rpu
kΩ
KHz
FSW
Maximum Switching Fre-
quency
10
RTH
Package Thermal Resistance
Single layer (1S) Jedec board
301
°C/W
Note: The output of SS732 will be switched after the supply voltage is over 2.2V, but the magnetic characteristics won't be normal
until the supply is over 3.5V.
Magnetic Specifications
DC Operating Parameters VDD = 3.5 to 24V (unless otherwise specified)
Package
Parameter
Symbol
BOP
Test Conditions
Min
5
Typ
23
Max
40
Units
G
Operating Point
Release Point
Hysteresis
Ta=25°C
UA
BRP
-40
-23
45
-5
G
Vdd=5V DC
BHYST
BOP
G
Operating Point
Release Point
Hysteresis
-40
5
-23
23
-5
G
Ta=25°C
SO
BRP
40
G
Vdd=5V DC
BHYST
45
G
Output Behavior versus Magnetic Pole
DC Operating Parameters TA = -40°C to 150°C, VDD = 3.5 to 24V (unless otherwise specified)
Test Conditions (UA) Test Conditions (SO)
OUT
High
Low
B < BRP
B > BOP
B > BRP
B < BOP
5