SS1365
Unipolar Hall Switch-Low Sensitivity
General Electrical Specifications
DC Operating Parameters TA = 25°C, VDD= 3.5V to 24V (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min
Typ
Max Units
Supply Voltage
Supply Current
VDD
IDD
Operating
3.5
1.5
24
5
V
mA
V
B < BRP
2.5
0.4
Output Saturation Voltage VDSon
IOUT = 20mA, B > BOP
B < BRP VOUT = 24V
RL = 1kΩ, CL = 20pF
RL = 1kΩ, CL = 20pF
0.5
10
Output Leakage Current
Output Rise Time
IOFF
tr
0.01
0.25
0.25
µA
µs
Output Fall Time
tf
µs
Magnetic Specifications
Package
Parameter
Symbol
Test Conditions
Min
Typ
Max Units
Operating Point
Release Point
Hysteresis
BOP
160
110
180
140
40
200
170
G
G
G
G
G
G
BRP
UA
Ta=25°C,Vdd=12V DC
BHYST
BOP
Operating Point
Release Point
Hysteresis
-200
-170
-180
-140
40
-160
-110
BRP
SO
Ta=25°C,V==12V DC
BHYST
Output Behavior versus Magnetic Pole
DC Operating Parameters TA = -40°C to 150°C, VDD = 3.5V to 24V (unless otherwise specified)
Test Conditions (UA) Test Conditions (SO)
OUT
B < BRP
B > BOP
B > BRP
B < BOP
High
Low
The SOT-23 device is reversed from the UA package. The SOT-23 output transistor will be turned on(drops low) in
the presence of a sufficiently strong North pole magnetic field applied to the marked face.
3