3951  
FULL-BRIDGE  
PWM MOTOR DRIVER  
Choosing a small value for RS essentially disables the  
current limiting during braking. Therefore, care should be  
taken to ensure that the motor’s current does not exceed  
the absolute maximum ratings of the device. The braking  
current can be measured by using an oscilloscope with a  
current probe connected to one of the motors leads.  
Similarly, when a transition of the PHASE input occurs,  
CT is discharged to near ground during the crossover delay  
time (the crossover delay time is present to prevent  
simultaneous conduction of the source and sink drivers).  
After the crossover delay, CT is charged by an internal  
current source of approximately 1 mA. The comparator  
output remains blanked until the voltage on CT reaches  
approximately 3.0 volts.  
CAUTION: Because the kinetic energy stored in the  
motor and load inertia is being converted into current,  
which charges the VBB supply bulk capacitance (power  
supply output and decoupling capacitance), care must be  
taken to ensure the capacitance is sufficient to absorb the  
energy without exceeding the voltage rating of any devices  
connected to the motor supply.  
Similarly, when the device is disabled via the ENABLE  
input, CT is discharged to near ground. When the device is  
re-enabled, CT is charged by the internal current source.  
The comparator output remains blanked until the voltage  
on CT reaches approximately 3.0 V.  
RC Fixed Off Time  
For most applications, the minimum recommended  
value is CT = 820 pF ±5 %. This value ensures that the  
blanking time is sufficient to avoid false trips of the com-  
parator under normal operating conditions. For optimal  
regulation of the load current, the above value for CT is  
recommended and the value of RT can be sized to deter-  
mine toff. For more information regarding load current  
regulation, see below.  
The internal PWM current control circuitry uses a one  
shot to control the time the driver remains off. The one  
shot time, toff (fixed off time), is determined by the selection  
of an external resistor (RT) and capacitor (CT) connected in  
parallel from the RC terminal to ground. The fixed off time,  
over a range of values of CT = 820 pF to 1500 pF and RT =  
12 kto 100 k, is approximated by  
toff = RTCT.  
LOAD CURRENT REGULATION WITH THE INTERNAL  
PWM CURRENT-CONTROL CIRCUITRY  
When the PWM latch is reset by the current compara-  
tor, the voltage on the RC terminal will begin to decay from  
approximately 3 volts. When the voltage on the RC  
terminal reaches approximately 1.1 volts, the PWM latch is  
set, thereby re-enabling the driver.  
During operation, the A3951Shave a lower limit to  
the range of PWM current control. This directly relates to  
the limitations imposed by the VREF input (2.0 V, minimum).  
RC Blanking  
Applications requiring a broader or full range (0% to  
100%) should utilize the A3952S, which are recom-  
mended for the improvements they bring to new designs.  
In addition to determining the fixed off time of the  
PWM control circuit, the CT component sets the compara-  
tor blanking time. This function blanks the output of the  
comparator when the outputs are switched by the internal  
current control circuitry (or by the PHASE, BRAKE, or  
ENABLE inputs). The comparator output is blanked to  
prevent false over-current detections due to reverse  
recovery currents of the clamp diodes, and/or switching  
transients related to distributed capacitance in the load.  
LOAD CURRENT REGULATION WITH EXTERNAL  
PWM OF THE PHASE OR ENABLE INPUTS  
The PHASE or ENABLE inputs can be pulse-width  
modulated to regulate load current. Typical propagation  
delays from the PHASE and ENABLE inputs to transitions  
of the power outputs are specified in the electrical charac-  
teristics table. If the normal PWM current control is used,  
then the comparator blanking function is active during  
phase and enable transitions. This eliminates false  
tripping of the over-current comparator caused by switch-  
ing transients (see RC Blankingabove).  
During internal PWM operation, at the end of the off  
time, the comparators output is blanked and CT begins to  
be charged from approximately 1.1 V by an internal current  
source of approximately 1 mA. The comparator output  
remains blanked until the voltage on CT reaches approxi-  
mately 3.0 volts.  