欢迎访问ic37.com |
会员登录 免费注册
发布采购

SA2102D 参数 Datasheet PDF下载

SA2102D图片预览
型号: SA2102D
PDF下载: 下载PDF文件 查看货源
内容描述: [Single Phase Kilowatt-hour Metering IC]
分类和应用:
文件页数/大小: 16 页 / 428 K
品牌: SAMES [ SAMES ]
 浏览型号SA2102D的Datasheet PDF文件第1页浏览型号SA2102D的Datasheet PDF文件第3页浏览型号SA2102D的Datasheet PDF文件第4页浏览型号SA2102D的Datasheet PDF文件第5页浏览型号SA2102D的Datasheet PDF文件第6页浏览型号SA2102D的Datasheet PDF文件第7页浏览型号SA2102D的Datasheet PDF文件第8页浏览型号SA2102D的Datasheet PDF文件第9页  
SA2102D  
sames  
ELECTRICAL CHARACTERISTICS  
(VDD = 2.5V, VSS = -2.5V, over the temperature range -10°C to +85°C#, unless otherwise specified. Refer to Figure 2 Test Circuit for  
Electrical Characteristics.)  
Symbol  
Typ  
Parameter  
General  
Min  
Max  
Unit  
Condition  
Supply Voltage:  
Positive  
VDD  
VSS  
IDD  
ISS  
2.25  
-2.75  
2.5  
2.75  
-2.25  
5
V
V
Supply Voltage:  
Negative  
Supply Current:  
Positive  
3.6  
3.6  
mA  
mA  
Supply Current:  
Negative  
2.5  
5
Inputs  
Current Sensor Inputs  
(Differential)  
Input Current Range  
IIP, IIN Offset Voltage  
-25  
+25  
µA  
Peak value  
IIP, IIN  
IIP, IIN  
-3.1  
+3.1  
mV  
Voltage Sensor Input  
(Asymmetrical)  
Input Current Range  
Offset Voltage  
IVP  
IVP  
-25  
+25  
µA  
Peak value  
-2.5  
+2.5  
mV  
Digital Inputs  
µA  
µA  
DIRI Input leakage  
DIRI  
IPD  
0.95  
140  
Pull down Current  
R2, R1, R0, FAST, CNF, SO  
80  
R2, R1, R), FAST, CNF, SO  
Input High Voltage  
Input Low Voltage  
V
V
VIH  
VIL  
VDD-1  
VSS+1  
Outputs  
Digital Outputs  
LED, DIRO  
Output High Voltage  
Output Low Voltage  
VDD-1  
V
V
ISOURCE = 5mA  
ISINK = 5mA  
VOH  
VOL  
VSS+1  
MON, MOP  
Output High Voltage  
Output Low Voltage  
V
V
ISOURCE = 15mA  
ISINK = 15mA  
VOH  
VOL  
4.4  
0.1  
# Extended Operating Temperature Range available on request.  
During manufacturing, testing and shipment we take great care to protect our products against potential external  
environmental damage such as Electrostatic Discharge (ESD). Although our products have ESD protection circuitry,  
permanent damage may occur on products subjected to high-energy electrostatic discharges accumulated on the human  
body and test equipment and can discharge without detection. Therefore, proper ESD precautions are recommended to  
avoid performance degradation or loss of functionality during product handling.  
ATTENTION!  
Electrostatic  
sensitive devices.  
Requires special  
handling.  
2/16  
http://www.sames.co.za