Magnet Sensor Usage Notes
Magnet Sensors are delicate products. Handle with extra care.
Do’s
When switching inductive or capacitive loads, use contact protection circuits.
Don’ts
Do not use ferro-magnetic mounting parts, screws, or other ferro-magnetic devices nearby. This will affect the sensitivity (AT).
When manual soldering, do not subject to more than a 5 second dwell. This may cause damage to the seals, change sensitivity,
and reduce solderability.
Do not drop. Dropping or subjection to shock will permanently damage the contact or alter the sensitivity (AT).
Switching voltage, switching current, and contact rating should not exceed maximum limits stated in specification sheets.
Due to continual improvement, specifications are subject to change without notice
www.reed-sensor.com
26 May 2004