欢迎访问ic37.com |
会员登录 免费注册
发布采购

RT6238A 参数 Datasheet PDF下载

RT6238A图片预览
型号: RT6238A
PDF下载: 下载PDF文件 查看货源
内容描述: [暂无描述]
分类和应用:
文件页数/大小: 23 页 / 489 K
品牌: RICHTEK [ RICHTEK TECHNOLOGY CORPORATION ]
 浏览型号RT6238A的Datasheet PDF文件第2页浏览型号RT6238A的Datasheet PDF文件第3页浏览型号RT6238A的Datasheet PDF文件第4页浏览型号RT6238A的Datasheet PDF文件第5页浏览型号RT6238A的Datasheet PDF文件第7页浏览型号RT6238A的Datasheet PDF文件第8页浏览型号RT6238A的Datasheet PDF文件第9页浏览型号RT6238A的Datasheet PDF文件第10页  
RT6238A/B  
will be triggered to shut down switching operation. If the  
UVP condition remains for a period, the RT6238 will retry  
automatically. When the UVP condition is removed, the  
converter will resume operation. The UVP is disabled  
during soft-start period.During hiccup mode, the shutdown  
time is determined by the capacitor at SS. A 2μA current  
source discharges VSS from its starting voltage (normally  
VPVCC). The IC remains shut down until VSS reaches  
0.2V, about 10ms for a 3.9nF capacitor. At that point the  
IC begins to charge the SS capacitor at 6μA, and a normal  
start-up occurs. If the fault remains, UVP protection will  
be enabled when VSS reaches 2.2V (typical). The IC will  
then shut down and discharge the SS capacitor from the  
2.2V level, taking about 4ms for a 3.9nF SS capacitor.  
synchronous rectifier turns on until the inductor current  
reaches zero current. If the output voltage remains high,  
then IC's switches remain off. If the output voltage exceeds  
the OVP trip threshold (1.2 times regulation level) for  
longer than 10μs (typical), the IC's OVP is triggered.  
RT6238AL chip enters latch mode.  
For RT6238BH, if the output voltage remains high, the  
synchronous rectifier remains on until the inductor current  
reaches the low side current limit. If the output voltage  
still remains high, the synchronous rectifier turns on and  
high-side MOSFET keeps off to operate at typical 500kHz  
switching protection, again if inductor current reaches low  
side current limit, the synchronous rectifier will turn off  
until next protection clock. RT6238BH is without OVP  
latch function and recover when OV condition release.  
Latch Mode  
For RT6238AH, if the output voltage remains high, the  
synchronous rectifier remains on until the inductor current  
reaches zero current. If the output voltage still remains  
high, then IC's switches remain off. RT6238AH is without  
OVP latch function and recover when OV condition release.  
For the RT6238AL/RT6238BL, it provides Latch-Off Mode  
Under Voltage Protection (UVP). When the FB voltage  
drops below 60% of the feedback reference voltage, the  
output voltage drops below the UVP trip threshold for longer  
than 270μs (typical) then IC's UVP is triggered. UVP  
function will be triggered to shut down switching operation.  
In shutdown condition, the RT6238 can be reset by EN  
pin or power input VIN.  
Latch-Off Mode  
The RT6238AL/BL uses latch-off mode OVP and UVP.  
When the protection function is triggered, the IC will shut  
down in Latch-Off Mode. The IC stops switching, leaving  
both switches open, and is latched off. To restart operation,  
toggle EN or power the IC off and then on again.  
Output Over-Voltage Protection  
If the output voltage VOUT rises above the regulation level  
and lower 1.2 times regulation level, the high-side switch  
naturally remains off and the synchronous rectifier turns  
on. For RT6238BL, if the output voltage remains high, the  
synchronous rectifier remains on until the inductor current  
reaches the low side current limit. If the output voltage  
still remains high, then IC's switches remain that the  
synchronous rectifier turns on and high-side MOS keeps  
off to operate at typical 500kHz switching protection, again  
if inductor current reaches low side current limit, the  
synchronous rectifier will turn off until next protection  
clock. If the output voltage exceeds the OVP trip threshold  
(1.2 times regulation level) for longer than 10μs (typical),  
then IC's output Over-Voltage Protection (OVP) is  
triggered. RT6238BL chip enters latch mode.  
Shut-Down, Start-Up and Enable (EN)  
The enable input (EN) has a shutdown level of 0.4V. When  
VEN is below this level the IC enters shutdown mode and  
supply current drops to less than 10μA. When VEN exceeds  
its logic-high level of 1.2V the IC is fully operational.  
Between these 2 levels there are 2 thresholds (1V typical  
and 1.2V typical). Switching operation begins when VEN  
exceeds the upper threshold, and then switching  
operation stops when VEN decreases to the lower  
threshold. Since EN is a low voltage input, it must be  
connected to VIN (up to 18V) with a 100kΩ pull-up resistor  
for automatic start-up.  
For RT6238AL, if the output voltage VOUT rises above  
the regulation level and lower 1.2 times regulation level,  
the high-side switch naturally remains off and the  
Copyright 2017 Richtek Technology Corporation. All rights reserved.  
©
is a registered trademark of Richtek Technology Corporation.  
www.richtek.com  
6
DS6238A/B-08 July 2017