AKL Sensors
Specifications:
Property
Min
4.5
3.2
Typ
4.0
8.0
50
Max
48
Unit
Input Voltage
Volts1
Supply Current in Off State
(Input Voltage=12V)
Supply Current in On State
(Input Voltage=12V)
4.8
mA2
mA2
7.0
9.0
Output Duty Cycle
40
-40
1.0
60
+150
3.5
%
°C
mm
Operating Temperature Range
AKL001-12 Airgap, Over Full Temperature and
Voltage Range4
AKL002-12 Airgap, Over Full Temperature and
1.0
0
2.5
mm
Voltage Range4
Frequency of Operation
ESD
10K
Hz
V3
2000
Absolute Maximum Ratings
Parameter
Limit
60V
Supply Voltage
Reverse Battery Voltage
-60V
Continuous Output Current
Junction Temperature Range
Storage Temperature Range
16mA
-40°C to +175°C
-65°C to +200°C
Signal Output
10
5
Current
Output
(mA)
Time
Notes:
1.
The supply voltage must appear across the power and ground terminals of the part. Any
additional voltage drop due to the presence of a series resistor is not included in this
specification.
2.
Supply currents can be factory programmed to different levels, for example 3mA and 6mA, or
7mA and 14mA; contact NVE for details.
3.
4.
Pin to pin voltage, Human Body Model for ESD
Airgap measured with standard ferrous gear tooth, contact NVE for details.
IC Drawings:
The AKL Series products use the ABL sensor elements described earlier in this section.
The AKL001-12 part uses the ABL004 sensor element, the AKL002-12 uses the ABL005
sensor element, and the AKL003-12 uses the ABL006 sensor element. Please see the IC
drawings in the ABL series section for more information.
R H O P O IN T C O M P O N E N T S
Tel: +44 (0) 870 608 1188 Fax: +44 (0) 870 241 2255
Web: www.rhopointcomponents.com Email: sales@rhopointcomponents.com