Status LEDs– Flash when
signals are sent/received
Sync/Pair Button – Press once to auto pair. See
Advanced operation for other pairing options.
Erase Button – Press and hold to erase all pairings, see
advanced operation for individual erase
Mag sync – Touch a
magnet to the plastic
case in the cross
hatched area to
replicate the sync
button on board
without opening the
case
Timer Select Button – Used to select timer mode
Signal Test mode – Press to enter signal test mode
Momentary/Latching selection – Make the link to select momentary
operation break the link for latching operation. (Default is latching)
POWER
8
SYNC
RELAY 1
RELAY 2
RELAY 3
RELAY 4
ERASE
7
6
5
4
3
2
1
TIMER
TEST
RELAY 4
RELAY 3
RELAY 1
RELAY 2
FUSE
L N E
L N E
L N E
L N E
L
N
E
Relay switch terminals:
Output Fuses must be 8A
(Slow blow fuses recommended)
110Vac power
input
Power input fuse – must be 500mA
(Fast blow fuse recommended)