FM REMOTE CONTROL SYSTEM.
FM-RCHN-XXXRS
DECODER CONNECTIONS
Ant
The decoder
L
N
Rx Decoder Module
(FM-DH0)
requires either a
single 12Vdc
supply or
0v 12v
240Vac mains.
LED 1 PSW
LINKS
RLY 4
RLY 3
RLY 2
RLY 1
WARNING
This appliance may be connected to the mains. The unit is design to be a fixed installation which may be
connected to the mains supply. Before removing the cover, ensure that the mains input supply is removed. Any
operation of the product that involves removal of the front cover should only be carried out by a competent
person or qualified electrician.
DATA OUTPUTS
Output 4 has a variable timed output which maybe adjusted from 10secs to 5 minutes. This is controlled by the
adjustable pot RV1.
Outputs 1 & 2 may be configured as momentary or latching operation by link 2 on the FM-DH0-418 decoder
module.
For use as a standard remote Control system Link 1 MUST be fitted.
RF DECODER LINKS 1 & 2
These links configure the mode of operation.
Configuration
Remote Control
Remote Control
Link 1
Connected
Connected
Open
Link 2
Open
Connected
Don’t Care
O/P1
Latch
Mom
O/P2
Latch
Mom
N/A
O/P3
Mom
Mom
Low
O/P4
Timed
Timed
Trig
For use with FM-ECAC
Auto Transmitting Encoder
Auto O/P
Battery
I/P’s
Note :
The Link status are read only on power up, after changing the links please remember
to remove and re-apply power.