119, 129  
10209  
KEELOQ REMOTE CONTROL SYSTEMS, 230Vac  
Data Outputs  
Each of the transmitter switches maps directly to the relay outputs. (SW1 to RLY1, SW2 to RLY2)  
Each output relay provides an isolated switch. Connections are Common (COM), Normally Open (NO) and  
Normally Closed (NC).  
Relay Connections when  
Transmitter NOT Operating  
Relay Connections when  
Transmitter OPERATING  
The jumper links ( LK1, LK2 ) configure the outputs to be momentary or latching.  
LK1  
Open  
Open  
LK2  
Open  
Connected  
Open  
O/P 1  
Mom  
Mom  
Latch  
Latch  
O/P2  
Mom  
Latch  
Mom  
Latch  
Connected  
Connected  
Connected  
Note : In momentary mode the relay will operate for as long as the transmitter switch is held on.  
Learning a new Transmitter Encoder  
To enter and activate the learn mode the following sequence must be performed.  
1. Power the receiver unit up and wait 10secs for the unit to enter ‘normal operation’ mode.  
2. Switch the receiver unit OFF and then ON again in ~1sec intervals four times finally leaving the unit  
powered up.  
3. After 5secs until a ‘beep’ sound is heard.  
4. The unit is now in ‘learn’ Mode.  
5. Briefly press a button on the transmitter, the receiver unit will ‘beep’ twice.  
6. Briefly Press the transmitter button again, he receiver unit will ‘beep’ three times.  
7. Wait 10sec for the unit to return to ‘normal operation’ mode.  
8. The transmitter is now ‘learnt’ to the receiver unit and will operate the output relays.  
Erasing Transmitter Encoders form Memory  
To enter and activate the erase mode the following sequence must be performed.  
1. Power the receiver unit up and wait 10secs for the unit to enter ‘normal operation’ mode.  
2. Switch the unit off and then on again in ~1sec intervals six times finally leaving the unit powered up.  
3. Wait 5secs until a ‘ticking’ sound is heard for a period of 10secs by the operation and release of one of the  
relays.  
4. Wait 10secs for the receiver unit to return to ‘normal’ mode  
5. The unit has now erased all encoder data.  
Note  
During Learn and Erase the relays should not be connected to equipment that will be harmed by rapid  
changes of the relay polarisation.  
DS119-5 June ‘06  