EUROLINE - DC/DC-Converter
RxxT and RxxU Series, 1 Watt, SIP7/DIP14, Isolated (Dual Output)
Electrical Specifications (measured at TA = 25°C, at nominal input voltage and rated output current unless otherwise specified)
Input Voltage Range VIN (continuous operation)
5V types
5V 10%
12V input types
12V 10%
Load Voltage Regulation (10% load to 100% full load)
3.3V and 5V output types
9V, 12V and 15V output types
15% max.
10% max.
Line Voltage Regulation
1.2% / 1.0% of VIN
See Tolerance Envelope
80mVp-p max.
Output Voltage Accuracy
Input Reflected Ripple (20MHz band limited)
Ouput Ripple (20MHz band limited)
Insulation Resistance (at 500VDC)
Efficiency (at full load)
75mVp-p max.
1000MΩ min.
3.3V and 5V output types
9V, 12V and 15V ouput types
65% min. / 70% typ.
70% min. / 80% typ.
Temperature Drift (VOUT
)
0.03% per °C max.
8°C max.
Temperature Rise above Ambient (at full load)
Switching Frequency at Full Load (depending on the type)
Package Weight
100kHz typ.
2.3 g
MTTF 1) (depending on the type)
–25°C
+25°C
+70°C
170kHrs min. / 1900kHrs max.
148kHrs min. / 1615kHrs max.
130kHrs min. / 1350kHrs max.
1). Calculated using MIL-HDBK-217F with nominal input voltage at full load.
Please contact us, if you need exact parameters for the converter you have selected.
Typical Characteristics, Tolerance Envelope and Temperature Derating Graph
R05T/Uxx
Tolerance Envelope
+10
+5
0
100
80
60
40
20
+10%
050503, 050505
050509
050509, 050515
+5%
+2,5%
– 2,5%
– 7,5%
V Nom.
050512
050503, 050505
050512
050515
-5
-10
10%
50%
100%
0
20 40 60 80 100
Total Output Current (%)
0
20 40 60 80 100
Total Output Current (%)
Output Load Current (%)
R12T/Uxx
Temperature Derating Graph
+10
+5
0
100
2.0
1.5
120509, 120512, 120515
120509, 120512
120503, 120505
80
60
40
20
1.0
120503,120505
Safe
Operating Area
120515
0.5
-5
0
-50
0
50 100 150
70 125
Ambient Temperature ˚C
-10
0
20 40 60 80 100
Total Output Current (%)
0
20 40 60 80 100
Total Output Current (%)
www.recom-international.com
EU 25