R0.5ZX
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
PROTECTIONS
Parameter
Type
Value
Short Circuit Protection (SCP)
below 100mW
continuous, automatic recovery
tested for 1 second
rated for 1 minute (7)
1kVDC
500VAC
standard
Isolation Voltage
I/P to O/P
tested for 1 second
rated for 1 minute (7)
2kVDC
1kVAC
with suffix “/H”
Isolation Resistance
Isolation Capacitance
10GW min.
100pF max.
1µA max.
2µA max.
standard
with suffix “/H”
Leakage Current
Insulation Grade
functional
Notes:
Note7:
Note8:
For repeat Hi-Pot testing, reduce the time and/or the test voltage
Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type
ENVIRONMENTAL
Parameter
Operating Temperature Range
Operating Altitude
Operating Humidity
Pollution Degree
Condition
Value
-40°C to +85°C
5000m
full load @ natural convection 0.1m/s (see graph)
non-condensing
5ꢀ - 95ꢀ RH max.
PD2
Vibration
according to MIL-STD-202G
+25°C
+85°C
23000 x 10³ hours
2000 x 10³ hours
MTBF
according to MIL-HDBK-217F, G.B.
Derating Graph
(@ Chamber and natural convection 0.1m/s)
100
ꢆ0
ꢅ0
ꢂ0
ꢃ0
50
ꢀ0
ꢄ0
ꢁ0
10
0
-ꢀ0 -ꢄ0 -ꢁ0 -10
0
10 ꢁ0 ꢄ0 ꢀ0 50 ꢃ0 ꢂ0 ꢅ0 ꢆ0 100 110
ꢅ5
Ambient Temperature [°C]
www.recom-power.com
REV.: 0/2019
ECO-3