● Replacement for R-78Axx-0.5SMD series
● RoHS 6/6 Conform (100% Lead Free)
● Efficiency up to 97%,Non isolated,
no need for heatsinks
INNOLINE
DC/DC-Converter
with 3 year Warranty
Features
● High Reflow Temperature SMD Package
● Adjustable Output Voltage
● Wide input range.(4.75V ~ 32V)
● Short circuit protection, Thermal shutdown
● Remote On/Off Control
0.5 AMP
SMD
● UL94V-0 Package Material
● Very Low Shutdown Current
● See Innoline Application Notes for use as an
inverter (alternative to LM79xx Linear)
Single Output
Description
The R-78AAxx-0.5SMD series are manufactured without lead and meet the requirements for RoHS 6/6 as well as
the increased reflow soldering temperatures associated with vapor phase soldering, making these high efficiency
switching regulators ideally suited to modern pick-and-place mass production. The efficiency of up to 97% means
that very little energy is wasted as heat. The additional features of remote on/off control and adjustable output
voltages will find many uses in the battery-powered, industrial, medical and automotive markets.
Selection Guide
Part
Number
SMD
Input
Range
(V)
Output
Voltage
(V)
Adjust
Range
(V)
Output
Current
(A)
Efficiency
Min. Vin Max. Vin
(%)
(%)
RoHS
2011/65/EU
6/6
R-78AA1.5-0.5SMD* 4.75 – 30
R-78AA1.8-0.5SMD* 4.75 – 32
R-78AA2.5-0.5SMD* 4.75 – 32
R-78AA3.3-0.5SMD* 4.75 – 32
R-78AA5.0-0.5SMD* 6.5 – 32
R-78AA6.5-0.5SMD* 8.0 – 32
R-78AA9.0-0.5SMD* 11 – 32
1.5
1.8
2.5
3.3
5.0
6.5
9.0
12
fixed
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
73
63
1.5~3.0
1.5~3.0
3.0~5.5
3.0~8.0
3.3~11.0
4.5~12.6
4.5~12.6
fixed
82
87
91
94
95
96
97
97
71
77
81
86
88
92
94
95
IEC/EN-60950-1 Certified
R-78AA-0.5
R-78AA12-0.5SMD*
R-78AA15-0.5SMD*
15 – 32
18 – 32
15
Derating-Graph
(Ambient Temperature)
Note 1:1.5V Output can be unstable with Vin>30VDC
* add suffix -R for tape&reel packing e.g. R-78AA5.0-0.5-R. For more details see Application Notes.
120
100
80
Standard Application Circuit
60
40
+Vout
+Vin
4,5
Safe Operating Area
1,2
R-78AAxx-0.5SMD
>1ms
20
0
R1
R2
C1
C2
6
10 3,7,8,9
85
10µF
(Optional)
-40
0
25
50
75
71
100
Off/On
GND
100µF
(Optional)
Operating Temperature (°C)
GND
To protect the converter from high inrush currents, use soft start Vin and C1=10µF
Output capacitor C2 recommended if load is very dynamic
Refer to Application Notes
I-7