INNOLINE
R-5xxxPA_DA
Series
DC/DC-Converter
Standard Application Circuit
11
R1
(Adjust down)
R-52XX
R-53XX
R-54XX
R-55XX
2, 3, 4
C1
9, 10
12
Vin
Vout
1µF
(Optional)
1
OFF
TTL
C2 (Req'd)
100µF/10V
or 220µF/10V
(see Note 1)
ON
R2
Q1
5, 6, 7,8
(Adjust up)
Com
Com
Parallel Application Circuit
The R-52xx, R-53xx, R-54xx series can be used in parallel to upgrade the output current capacity for
the same output voltage.
For example, the R-543.3PA can parallel up with another R-554.3PA to give up to 8 amps or with the
R-533.3PA or R-523.3PA types to give output currents of up to 7 Amps or 6 Amps.
The R-55xx series cannot be paralleled.
1
2
3
4
12
11
10
9
Vin
U1
Vout
Com
8
5
6
7
Q1
C1
ON/OFF
Control
100µF/25V
(REQ`D)
C2-1
100µF/10V
(REQ`D)
Com
C2-2
100µF/10V
(REQ`D)
4
3
2
1
8
9
10
11
12
5
6
7
U2
must be connected
together
Component side
Solder side
C1
12
1
1
U1
12
1
U1
U2
C2-1
U2
12
1
12
Keep 2mm to 5mm distance
between both converters
C2-2
To Load
www.recom-international.com
130
24-August-2005