FM24CL64  
Overview  
Two-wire Interface  
The FM24CL64 is a serial FRAM memory. The  
memory array is logically organized as a 8,192 x 8 bit  
memory array and is accessed using an industry  
standard two-wire interface. Functional operation of  
the FRAM is similar to serial EEPROMs. The major  
difference between the FM24CL64 and a serial  
EEPROM with the same pinout relates to its superior  
write performance.  
The FM24CL64 employs a bi-directional two-wire  
bus protocol using few pins or board space. Figure 2  
illustrates a typical system configuration using the  
FM24CL64 in a microcontroller-based system. The  
industry standard two-wire bus is familiar to many  
users but is described in this section.  
By convention, any device that is sending data onto  
the bus is the transmitter while the target device for  
this data is the receiver. The device that is controlling  
the bus is the master. The master is responsible for  
generating the clock signal for all operations. Any  
device on the bus that is being controlled is a slave.  
The FM24CL64 always is a slave device.  
Memory Architecture  
When accessing the FM24CL64, the user addresses  
8,192 locations each with 8 data bits. These data bits  
are shifted serially. The 8,192 addresses are accessed  
using the two-wire protocol, which includes a slave  
address (to distinguish other non-memory devices),  
and an extended 16-bit address. Only the lower 13  
bits are used by the decoder for accessing the  
memory. The upper three address bits should be set  
to 0 for compatibility with larger devices in the  
future.  
The bus protocol is controlled by transition states in  
the SDA and SCL signals. There are four conditions  
including start, stop, data bit, or acknowledge. Figure  
3 illustrates the signal conditions that specify the four  
states. Detailed timing diagrams are in the electrical  
specifications.  
The access time for memory operation is essentially  
zero beyond the time needed for the serial protocol.  
That is, the memory is read or written at the speed of  
the two-wire bus. Unlike an EEPROM, it is not  
necessary to poll the device for a ready condition  
since writes occur at bus speed. That is, by the time a  
new bus transaction can be shifted into the part, a  
write operation will be complete. This is explained in  
more detail in the interface section below.  
VDD  
Rmin = 1.1 K  
Rmax = tR/Cbus  
Microcontroller  
SDA SCL  
FM24CL64  
A0 A1 A2  
SDA SCL  
FM24CL64  
A0 A1 A2  
Users expect several obvious system benefits from  
the FM24CL64 due to its fast write cycle and high  
endurance as compared with EEPROM. However  
there are less obvious benefits as well. For example  
in a high noise environment, the fast-write operation  
is less susceptible to corruption than an EEPROM  
since it is completed quickly. By contrast, an  
EEPROM requiring milliseconds to write is  
vulnerable to noise during much of the cycle.  
Figure 2. Typical System Configuration  
Note that it is the user’s responsibility to ensure that  
VDD is within datasheet tolerances to prevent  
incorrect operation.  
Rev. 3.1  
Mar. 2005  