欢迎访问ic37.com |
会员登录 免费注册
发布采购

FM24C64-G 参数 Datasheet PDF下载

FM24C64-G图片预览
型号: FM24C64-G
PDF下载: 下载PDF文件 查看货源
内容描述: 64Kb的FRAM串行存储器 [64Kb FRAM Serial Memory]
分类和应用: 存储内存集成电路静态存储器光电二极管
文件页数/大小: 12 页 / 98 K
品牌: RAMTRON [ RAMTRON INTERNATIONAL CORPORATION ]
 浏览型号FM24C64-G的Datasheet PDF文件第2页浏览型号FM24C64-G的Datasheet PDF文件第3页浏览型号FM24C64-G的Datasheet PDF文件第4页浏览型号FM24C64-G的Datasheet PDF文件第5页浏览型号FM24C64-G的Datasheet PDF文件第7页浏览型号FM24C64-G的Datasheet PDF文件第8页浏览型号FM24C64-G的Datasheet PDF文件第9页浏览型号FM24C64-G的Datasheet PDF文件第10页  
FM24C64  
Address and Data  
By Master Start  
Stop  
A P  
DEVICE ADDRESS  
0
ADDRESS LSB  
ADDRESS MSB  
X X X  
DATA BYTE  
A
A
A
S
By FM24C64  
ACKNOWLEDGE  
Figure 5. Byte Write  
Address and Data  
By Master Start  
Stop  
DEVICE ADDRESS  
ADDRESS LSB  
DATA BYTE  
ADDRESS MSB  
X X X  
DATA BYTE  
0
A
A
A
A
A P  
S
By FM24C64  
ACKNOWLEDGE  
Figure 6. Multiple Byte Write  
attempts to read out additional data onto the bus. The  
four valid methods are:  
Read Operation  
There are two basic types of read operations. They  
are current address read and selective address read. In  
a current address read, the FM24C64 uses the internal  
address latch to supply the address. In a selective  
read, the user performs a procedure to set the address  
to a specific value.  
1. The bus master issues a no-acknowledge in the  
9th clock cycle and a stop in the 10th clock cycle.  
This is illustrated in Figures 7-9. This is the  
preferred method.  
2. The bus master issues a no-acknowledge in the  
9th clock cycle and a start in the 10th.  
3. The bus master issues a stop in the 9th clock  
cycle.  
Current Address & Sequential Read  
The FM24C64 uses an internal latch to supply the  
address for a read operation. A current address read  
uses the existing value in the address latch as a  
starting place for the read operation. The system  
reads from the address immediately following that of  
the last operation.  
4. The bus master issues a start in the 9th clock  
cycle.  
If the internal address reaches 1FFFh, it will wrap  
around to 0000h on the next read cycle. Figures 7 and  
8 show the proper operation for current address reads.  
To perform a current address read, the bus master  
supplies a device address with the LSB set to 1. This  
indicates that a read operation is requested. After  
receiving the complete device address, the FM24C64  
will begin shifting out data from the current address  
on the next clock. The current address is the value  
held in the internal address latch. Beginning with the  
current address, the bus master can read any number  
of bytes. Thus, a sequential read is simply a current  
address read with multiple byte transfers. After each  
byte the internal address counter will be incremented.  
Selective (Random) Read  
There is a simple technique that allows a user to  
select a random address location as the starting point  
for a read operation. This involves using the first  
three bytes of a write operation to set the internal  
address followed by subsequent read operations.  
To perform a selective read, the bus master sends out  
the device address with the LSB set to 0. This  
specifies a write operation. According to the write  
protocol, the bus master then sends the address bytes  
that are loaded into the internal address latch. After  
the FM24C64 acknowledges the address, the bus  
master issues a start condition. This simultaneously  
aborts the write operation and allows the read  
command to be issued with the device address LSB  
set to a 1. The operation is now a current address  
read.  
Each time the bus master acknowledges a byte, this  
indicates that the FM24C64 should read out the next  
sequential byte.  
There are four ways to properly terminate a read  
operation. Failing to properly terminate the read will  
likely create a bus contention as the FM24C64  
Rev. 3.0  
Mar. 2005  
6 of 12