FM1114 NV Quad State Saver
AC Parameters (TA = -40° C to + 85° C, VDD = 2.7V to 3.6V, CL = 30 pF unless otherwise specified)
Symbol
Parameter
Min
Max
Units
Notes
fMAX
tLOW
tHIGH
tPD
Maximum Clock Frequency
CLK Low Period
1
MHz
µs
µs
ns
0.3
0.3
CLK High Period
Propagation delay CLK to QN
EN Low to QN Hi-Z
Input Rise Time
50
25
100
100
tHZ
ns
1
1
1
tR
ns
tF
Input Fall Time
ns
tDS
Data (DN) Setup Time to CLK
↑
5
10
0
5
2
ns
tDH
tEHD
tEH
Data (DN) Hold Time after CLK
↑
ns
EN Hold Time (EN High after CLK
EN High Time
↑
)
µs
µs
µs
tEL
EN Low Time
Notes
1. This parameter is characterized but not tested.
Power Cycling and Data Retention (TA = -40° C to + 85° C, VDD = 2.7V to 3.6V, unless otherwise specified)
Symbol
Parameter
Nonvolatile Data Retention Time
VDD Rise Time
Min
45
0.1
0.1
-
Max
Units
years
µs/V
µs/V
µs
Notes
-
-
-
0.5
-
-
tVDR
tVDF
tRES
tPDS
tEHFC
1
1
2
VDD Fall Time
EN High to QN Restore Time
EN Low to Power Down Time
1
µs
EN High to First Clock (CLK
↑
) after Power Up
4
3
µs
Notes
1. Slope measured at any point on VDD waveform.
2. After power up, when EN goes high the nonvolatile latches are read and the values restored to the outputs QN.
3. After power up, this is the minimum time required before a state change operation may occur. EN and VDD may be
coincident at power up, and in this case tEHFC time is referenced to VDD (min) and CLK .
↑
Capacitance (TA = 25° C , f=1.0 MHz, VDD = 3.3V)
Symbol
CI
Notes
Parameter
Min
-
Max
14
Units
pF
Notes
1
Input Capacitance
1. This parameter is characterized but not tested.
Rev. 1.1
Aug. 2007
Page 5 of 8