Pin description of TR2M with Modem mode selected  
The 'modem' mentioned is a 1200 baud RS232 semi-intelligent unit (Transmit keyed when valid serial data is  
present, so no separate TX control needed. Coding in the datastream also permits the receiver to ignore noise  
and only output valid serial data). This is a half duplex unit, so collisions between transmitted and received  
packets must be dealt with by the user.  
Pin  
1
Name  
Function  
MOD TX_ON  
MOD NC  
MOD NC  
RSSI  
Open = normal modem operation. Low = constant TX (for test). 10k pullup to 4V  
2
Leave open  
Leave open  
3
4
DC level between 0.5V and 2.5V. 60dB dynamic range  
Leave open  
5
MOD NC  
AF out  
6
Modem tones or noise present  
NC  
Leave open  
7
8
+4.4V out  
Regulated DC supply. 75mA max. drain. Present if unit is powered  
Ground  
9
0V  
10  
11  
12  
13  
PGM  
Serial programming/configuration input at RS232 level  
RS232 data input (true). 10k pullup to 4V  
Inverted RS232 data out (to inverting buffer like MAX232)  
Leave open  
MOD TXD  
MOD RXD  
MOD NC  
TR2Ms on both ends should be configured to required operating frequency using GOCHAN  
command before starting to use the internal 1200 baud modem, because the P1-P3 pins will be used  
as Modem Data pins and the modem will operate on the last serially selected channel after  
SETMOD command is used to enable the Modem.  
TXE (MOD TX_ON) (C1)  
TXD (MOD NC) (C2)  
AF in (MOD NC) (C3)  
RSSI (C4)  
SQF (MOD NC) (C5)  
AF out (C6)  
RXD (MOD NC) (C7)  
+4.4V out (C8)  
GND (C9)  
Serial COM Port  
1
6
2
RXD  
PGM (C10)  
7
8
9
3
SW1  
TXD  
P1 (MOD TXD) (C11)  
P2 (MOD RXD) (C12)  
P3 (MOD NC) (13)  
VDD  
4
SGD  
5
RS232 driver  
Figure 7: TR2M interfaced to PC serial port in modem mode  
Note:  
Baud rate used for Modem is half that of used for serial configuration. Attached RS232 devices  
should be set with the following:  
1200bps, 8 Data bits, No Parity, 1/2 stop bits, no flow control  
TXD (Pin 3) of a Serial Port can be switched from PGM (Pin C10) to MOD TXD (Pin C11) with no  
RS232 driver in between. However, MOD RXD (Pin C12) requires an RS232 line driver before it  
can be connected to RXD (pin 2) of a serial port. Some of the RS232 line drivers can be powered  
from the regulated +4.4V out (Pin C8).  