Operation Modes  
The MTX2 has three different modes of operation:  
1. Parallel. By default the MTX2 operates on one of the four channels selected by the parallel input pins. At  
power up, or when a change of parallel input is detected, the current frequency coefficients are loaded from  
the eeprom stores corresponding to parallel channels 0-3. The parallel input consists of an inverted 2 bit  
binary number applied to P0/P1 (often from a 2 pole switch)  
2. Sequential. If a (sequential) channel is programmed over the serial port, the unit sets it's operating  
frequency according to this channel number, the programmed table start frequency and the currently  
programmed table step size. If the channel is set to zero, the unit returns to default parallel operation.  
If the (sequential) channel is programmed into eeprom, the unit will default to this channel at power up  
The table can be considered to be a 255 entry table, starting at channel 1, with the frequency incrementing  
by the programmed step size for each increment in channel number (it can be seen that, if a 256 entry table  
starting with channel zero is desired then programming all the parallel channels to the ch0 frequency, and  
the sequential table start value to ch1 will achieve this)  
3. Direct. Whenever a frequency coefficient is programmed into the unit, the frequency will change  
immediately to this new value regardless of other modes or operation. This is the simplest and most flexible  
means of controlling the unit.  
If a unit is set in sequential table mode (ie: channel value isn't zero), then direct programming cannot be  
used to over-ride the selected channel (executing an @PRG_iiffffff will just set up a set of frequency  
coefficients ready to be written to rom. It won't change the actual operating frequency)  
Serial interface commands  
MTX2 serial interface consists of an inverted RS232 datastream (9600 baud, 1+8+1, no parity) applied to the  
EN pin (the idle state of the interface will turn the transmitter on)  
Every command string starts with the phrase "@PRG_"  
The characters in a command string must not be separated by more than 5mS (so typing individual  
characters on a terminal keyboard will NOT work), but a pause of at least 10mS is required between  
commands (more following a BURN_ROM command. In this case a much longer idle period, of 50mS at  
least, is needed for eeprom programming)  
Frequency setting commands  
Commands  
@PRG_iiffffff <cr>  
Function  
sets the current (temporary) frequency  
iiffffff is an 8 digit hexadecimal number (4 bytes):  
ii is the 1 byte "integer" coefficient  
ffffff is the 3 byte "fraction" coefficient  
Frequency (in MHz) = 6.5 x integer + 6.5 x (fraction/2^19)  
The component (fraction/2^19) must be in the range 1-2  
@PRG_BURN_CH0 <cr>  
@PRG_BURN_CH1 <cr>  
@PRG_BURN_CH2 <cr>  
@PRG_BURN_CH3 <cr>  
write current frequency into channel 0 eeprom  
write current frequency into channel 1 eeprom  
write current frequency into channel 2 eeprom  
write current frequency into channel 3 eeprom  
(these functions do NOT program band/power/offset values)  