 浏览型号LMR2-458-5-12K5的Datasheet PDF文件第2页浏览型号LMR2-458-5-12K5的Datasheet PDF文件第3页浏览型号LMR2-458-5-12K5的Datasheet PDF文件第4页浏览型号LMR2-458-5-12K5的Datasheet PDF文件第5页浏览型号LMR2-458-5-12K5的Datasheet PDF文件第7页浏览型号LMR2-458-5-12K5的Datasheet PDF文件第8页浏览型号LMR2-458-5-12K5的Datasheet PDF文件第9页浏览型号LMR2-458-5-12K5的Datasheet PDF文件第10页  
Serial interface commands  
2400 baud RS232. 8 bit data, no parity, 1 start bit, 1 or 2 stop bits.  
Serial data is sent to the unit on one of the parallel channel select pins (P0). It is very important that  
the unit does not 'decode' switch bounce in ordinary operation as a command string, or spurious re-  
writing of the e2prom will result. For this reason the user must send the 16 character string  
ENABLESERIALMODE (followed by a carriage return) to activate the serial command mode before  
sending any of the command strings listed below. Command mode is disabled on power down, or on  
reception of a # character. To successfully program the unit, it must be enabled ('RXE high (rx) or TXE  
low (tx)).  
GOCHAN aa  
LOAD aa nnnnn  
SETPAR  
SETSER  
RVALUE rrrr  
SINGLE nnnnn  
Serially select channel aa, where aa is ch0 to ch31  
Set value of N register for channel aa, where aa is Channels 0 to 31  
Channel selected by 4 bit parallel inputs (ch0 to ch15 only)  
Channel selected by most recent GOCHAN operation  
Set value for R register  
Set value of N for single channel operation.  
N value NOT stored in EEPROM  
<cr>  
Process entry  
/
Clear all buffers  
#
Disable command mode  
aa = a two digit channel number from 00 to 31  
nnnnn = synthesizer N register value (up to 65535)  
rrrr = synthesizer R register value (up to 16383)  
fTCXO  
fRF  
13MHz  
25kHz  
433.900MHz  
25kHz  
NTX  
=
=
=
=17356  
R =  
=
, So R=520  
fChannelspacing  
fchannelspacing  
fRF 21.4MHz  
433.900MHz 21.4  
25kHz  
NRX  
=
=16500  
fChannelspacing  
Note: A pause of at least 50ms must be allowed between command strings (EEPROM  
programming time).  
SINGLE mode does not store the N value in EEPROM. Therefore the unit is inoperative  
after a power down until either another valid SINGLE command is received, or mode is  
changed by a GOCHAN, SETPAR or SETSER command. SINGLE mode is intended for  
frequency agile applications.  