Hartcran House, 231 Kenton Lane, Harrow, Middlesex, HA3 8RP, England
Tel: +44 (0) 20 8909 9595, Fax: +44 (0) 20 8909 2233, www.radiometrix.com
CXT/CXR
Issue 1, 27 July 2012
Multi channel 25kHz NBFM remote control TX/RX
The CXT transmitter and CXR receiver
modules offer a multi channel, low power,
and reliable remote control data link. This
makes the CXT/CXR pair ideally suited to
those low power applications where
existing
wideband
modules
have
insufficient range, or where low cost multi-
channel operation is needed without
compromising on RF specification or
regulatory requirement.
Figure 1: CXT2 transmitter and CXR2 receiver
Features
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Conforms to EN 300 220-3 and EN 301 489-3
High performance double superhet. PLL synthesizer with TCXO
SAW front-end filter
Usable range over 1km
16 bit unit address (65535 unique addresses)
Momentary and Latched outputs
Fully screened. Low profile
Re-programmable via RS232 interface
Low power requirements
Applications
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Industrial telemetry and telecommand
HVAC controls
Wireless door entry systems
Simple On/Off switching
In-building environmental monitoring and control
High-end security and fire alarms
Heavy vehicle/machinery controls
Status reporting and monitoring secure systems
Technical Summary
ꢀ
Operating frequency: 173.200 - 173.325MHz (UK band)
150.825 - 152.450MHz (Australian Band)
433.875 - 434.650MHz (EU band)
458.525 - 459.1MHz (UK band)
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Other custom VHF and UHF bands
32 channels @ 25kHz channel spacing
Transmit power: +10dBm (10mW) / +20dBm (100mW)
Supply range: 3.1 – 15V (TX @ 10mW and RX), 4.1 – 15V (TX @ 100mW)
Current consumption: 34mA @ 10mW, 90mA @ 100mW (transmit) and 20mA (receive)
Receiver sensitivity: -118dBm (for 12 dB SINAD)
Serial configuration by inverted RS232 at 3V CMOS level
Radiometrix Ltd
CXT/CXR – Multi channel Remote Controller Data Sheet
page 1