Displays
ANDpSi0089C362S-KIT
Timing Specifications (see Notes below)
Signal
Item
Symbol
ts
Min
19.0
–
Typ
Max
Unit
ns
MHz
ns
ns
ns
–
Frame Period
Frequency
high Time
19.84
–
1/ts
tsh
tsl
50.4
–
52.6
NCLK
6
–
Low Time
7
–
–
Setup to NCLK
Pulse Width
tls
7
–
–
HSYNC
VSYNC
tlw
8 x ts
3 x tlpd
7 x tlpd
16
–
–
Pulse Width
tfw
tfd
–
7 x tlpd
–
VSYNC to DATA
Setup to HSYNC
–
–
–
–
tfl
–
ns
1320 x ts
25.08
1344 x ts
26.67
1344 x ts
–
µs
Line Period
tlpd=tlpl
–
Horizontal Display Time
Frame Frequency
Frame Period
Vertical Display Time
Setup
thd
1/tfpd
tfpd=tfpf
tvd
1024 x ts
1024 x ts
1024 x ts
–
Hz
–
56
60
–
–
610 x tlpd
625 x tlpd
635 x tlpd
600 x tlpd
600 x tlpd
600 x tlpd
–
tds
5
7
–
–
–
–
–
–
ns
ns
ns
ns
–
DATA
DE
Hold
tdh
–
Setup
tdrs
10
10
–
–
–
Hold
tdrh
Display Start
tdrds
400 x ts
Notes:
Refer to “Timing Chart” below. If NCLK is fixed to “H” or “L” level for certain period while VDD is supplied, the panel may be damaged. Please adjust
LCD operating signal timing and FL driving frequency, to optimized the display quality.There is a possibility that flicker is observed by the interference
of LCD operating signal firing and FL driving condition (especially driving frequency), even if the condition satisfied above timing specifications. Do
not make tv, tvhd and tvds fluctuate. If tv, tvhd, and tvds are fluctuating, the panel displays black. In case of using the long frame period, the deteriora-
tion of display quality, noise, etc., may be occurring. NCLK count of each Horizontal Scanning Time should always be the same. V-Blanking period
should be “n” X “Horizontal Scanning Time”. (n:integer) Frame period should always be the same.
Timing Chart
Purdy Electronics Corporation • 720 Palomar Avenue • Sunnyvale, CA 94085
4