 浏览型号INN3266C-H204-TL的Datasheet PDF文件第3页浏览型号INN3266C-H204-TL的Datasheet PDF文件第4页浏览型号INN3266C-H204-TL的Datasheet PDF文件第5页浏览型号INN3266C-H204-TL的Datasheet PDF文件第6页浏览型号INN3266C-H204-TL的Datasheet PDF文件第8页浏览型号INN3266C-H204-TL的Datasheet PDF文件第9页浏览型号INN3266C-H204-TL的Datasheet PDF文件第10页浏览型号INN3266C-H204-TL的Datasheet PDF文件第11页  
InnoSwitch3-CP  
Cable Drop Compensation (CDC)  
The amount of cable drop compensation is a function of the load with  
respect to the constant current regulation threshold as illustrated in  
Figure 9.  
ꢈ ꢉ ꢊꢋꢌ  
ꢓꢗꢜꢖe Dꢝꢑꢞ  
ꢓꢑꢟꢞeꢎꢏꢗꢐꢘꢑꢎ  
Auto-Restart Thresholds  
The OUTPUT VOLTAGE pin includes a comparator to detect when the  
output voltage falls below VFB(AR) or VVOUT(AR), for a duration exceeding  
tFB(AR) or tVOUT(AR)respectively. The secondary controller will relinquish  
control when this fault condition is detected. This threshold is meant  
to limit the range of constant current (CC) operation and is included  
to support high power charger applications.  
ꢋꢌ  
ꢙꢑꢂꢚꢑꢗꢛ  
ꢍꢎꢏeꢐ ꢑꢒ ꢓꢓ  
Reꢔꢕꢖꢗꢐꢘꢑꢎ  
SECONDARY BYPASS Pin Overvoltage Protection  
ꢀoꢁꢂ Cꢃꢄꢄꢅnt  
The InnoSwitch3-CP secondary controller features a SECONDARY  
BYPASS pin OV feature similar to the PRIMARY BYPASS pin OV feature.  
When the secondary is in control, in the event that the SECONDARY  
BYPASS pin current exceeds IBPS(SD) (~7 mA) the secondary will send a  
command to the primary to initiate an auto-restart off-time (tAR(OFF)) or  
latch-off (see Secondary Fault Response in Feature Code Addendum).  
ꢀꢁꢂ80ꢃꢄꢂ0ꢅꢆꢄ1ꢇ  
Figure 9. Cable Drop Compensation Characteristics.  
During normal operation, the secondary will stop requesting pulses  
from the primary to initiate an auto-restart cycle when the FEEDBACK  
pin voltage falls below the VFB(OFF) threshold. The deglitch filter on the  
protection mode is on for less than ~10 ms. By this mechanism, the  
secondary will relinquish control after detecting that the FEEDBACK  
pin is shorted to ground.  
Output Constant Current and Constant Power Regulation  
The InnoSwitch3-CP regulates the output current through an external  
current sense resistor between the ISENSE and SECONDARY  
GROUND pins and also controls output power in conjunction with the  
output voltage sensed on the OUTPUT VOLTAGE pin. If constant  
Reꢐꢈeꢑꢉ ꢒꢓꢔꢕꢌꢖ  
ꢇꢈꢉꢊꢈꢉ ꢋꢌꢍꢉꢎꢏe  
ꢀiꢁꢂ  
ꢀiꢁꢂ  
Figure 10. Intelligent Quasi-Resonant Mode Switching.  
7
Rev. D 08/18  
www.power.com