DPA422-426  
saturation due to large load transients in forward converter  
applications. DCMAX of 33% at the OV threshold was chosen to  
ensure that the power capability of the DPA-Switch is not  
restricted by this feature under normal operation.  
DPA-Switch is held in remote-off state for longer than 10 µs  
(typical), the CONTROL pin goes into the hysteretic mode of  
operation. In this mode, the CONTROL pin goes through  
alternate charge and discharge cycles between 4.8 V and 5.8 V  
(see CONTROL Pin Operation section above) and the IC runs  
entirely off the high-voltage DC input, but with very low power  
consumption (30 mW typical at 48 V with LINE-SENSE and  
EXTERNAL CURRENT LIMIT pins open). When the DPA-Switch  
is remotely turned on after entering this mode, it will initiate a  
normal start-up sequence with soft-start the next time the  
CONTROL pin reaches 5.8 V. In the worst case, the delay from  
remote on to start-up can be equal to the full discharge/charge  
cycle time of the CONTROL pin, which is approximately 36 ms  
for a 22 µF CONTROL pin capacitor. This reduced-consumption  
remote-off mode can eliminate expensive and unreliable in-line  
mechanical switches. It also allows for microprocessor-  
controlled turn-on and turn-off sequences that may be required  
in certain applications.  
Remote ON/OFF  
Remote ON/OFF control describes operation where the IC is  
turned on or off for long periods as opposed to the cycle-by-  
cycle on/off control, which is described in the Synchronization  
section below.  
DPA-Switch can be turned on or off by controlling the current  
into the LINE-SENSE pin or out from the EXTERNAL CURRENT  
LIMIT pin (see Figure 7). This allows easy implementation of  
remote ON/OFF control of DPA-Switch in several different ways.  
A transistor or an optocoupler output connected between the  
EXTERNAL CURRENT LIMIT pin and the SOURCE pin  
implements this function with “active-on” (Figures 17, 19 and 21)  
while a transistor or an optocoupler output connected between  
the LINE-SENSE pin and the CONTROL pin implements the  
function with “active-off” (Figures 18, 20 and 22).  
Synchronization  
In addition to sensing incoming current for OV, UV and remote  
ON/OFF, the LINE-SENSE pin also monitors its pin voltage  
through a 1 V threshold comparator. A pin voltage below 1 V  
turns on DPA-Switch. When the voltage at LINE-SENSE pin  
rises beyond 1 V to disable the output, DPA-Switch completes  
its current switching cycle before the output is forced off (similar  
to remote ON/OFF operation). The internal oscillator is stopped  
at the end of the current cycle awaiting the LINE-SENSE pin  
voltage to go low to start the next cycle. This allows the use of  
the 1 V threshold to synchronize DPA-Switch to an external  
signal with a frequency lower than its internal switching  
frequency. A transistor or an optocoupler output connected  
between the LINE-SENSE pin and the SOURCE pin implements  
this function (see Figure 24). Please refer to Figure 6 for the  
timing waveforms of synchronization operation.  
When a signal is received at the LINE-SENSE pin or the  
EXTERNAL CURRENT LIMIT pin to disable the output through  
any of the pin functions such as OV, UV and remote ON/OFF,  
DPA-Switch always completes its current switching cycle before  
the output is forced off. The internal oscillator is stopped at the  
end of the current cycle and stays there as long as the disable  
signal exists. When the signal at the above pins changes state  
from disable to enable, the internal oscillator starts the next  
switching cycle.  
The remote ON/OFF feature can be used as a standby or power  
switch to turn off the DPA-Switch and keep it in a very low  
power consumption state for indefinitely long periods. If the  
f
128 kHz;  
t
£ 7.7 µs; 120 ns £ t  
£ 2250 ns for f  
£ 3080 ns for f  
= 400 kHz  
= 300 kHz  
SYNC  
OFF  
ON  
OSC  
OSC  
Oscillator  
(SAW)  
D
MAX  
2 V  
0 V  
Time  
V
L
t
ON  
t
OFF  
ON  
OFF  
SYNC  
PI-2762-070501  
Figure 6. Synchronization Timing Diagram.  
7
www.powerint.com  
Rev. T 12/12