DI-55
Key Design Points
TRANSFORMER PARAMETERS
• For good cross-regulation, minimize transformer leakage
- use foil for 3.3 V and 5 V outputs; minimize peak
primary currents by designing transformer for continuous
conduction mode.
EEL25, N67 or equivalent,
Core Material
gap for ALG of 202 nH/T2
7 pin + 7 pin
Bobbin
• Shunt regulator (temperature compensated) between 5 V
and 3.3 V outputs in dotted box on schematic is optional.
It is only necessary where min and max load conditions
do not occur simultaneously on both outputs.
• Feedback is taken from both the 3.3 V and 5 V outputs to
the reference (U3) via R9, R11 and R12. The 12 V output
is DC stacked on the 5 V output for enhanced regulation
and voltage centering.
• Primary clamp components VR1, D5, R7, R1 and C2 limit
the leakage inductance induced peak drain voltage spike.
• D5 is a slow recovery diode to recover some of the clamp
energy. It must be a glass passivated type to guarantee a
defined trr.
Shield 1: 32T, 2 x 32 AWG
Primary: 63T, 2 x 32 AWG
Bias: 6T, 4 x 32 AWG
Winding Details
Shield 2: 4T, 4 x 32 AWG
3.3 V/5 V foil: 2T + 1T, 0.12 mm foil
-24 V: 13T, 2 x 32 AWG
+12 V: 4T, 4 x 32 AWG
Shield (NC-1), tape, primary
(1-4), tape, bias (5-7),
tape, shield 2 (13-NC),
foil (10,11-9-13), -24 V
(14-10,11), 12 V (12-8).
Winding Order
(pin numbers)
Primary: 800 µH ±10%
Leakage: 80 µH (max.)
Inductance
Primary Resonant
Frequency
• Use a Zener clamp for lowest zero load input power
consumption.
300 kHz (minimum)
Table 1. Transformer Design Parameters.
Load
Range
(A)
Regulation (%)
Voltage
(V)
-5 -4 -3 -2 -1
0
1
2
3
4
5
6
7
3.3
5
12
0.3-0.6
0.3-1.2
0.1-0.2
-24
0.03-0.05
Table 2. Worst Case Output Cross-Regulation - all Outputs Taken
from Minimum to Maximum Loads.
For the latest updates, visit www.powerint.com
Power Integrations reserves the right to make changes to its products at any time to improve reliability or manufacturability. Power Integrations does
not assume any liability arising from the use of any device or circuit described herein. POWER INTEGRATIONS MAKES NO WARRANTY HEREIN AND
SPECIFICALLY DISCLAIMS ALL WARRANTIES INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A
PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF THIRD PARTY RIGHTS. The products and applications illustrated herein (transformer
construction and circuits external to the products) may be covered by one or more U.S. and foreign patents or potentially by pending
U.S. and foreign patent applications assigned to Power Integrations. A complete list of Power Integrations' patents may be found at
www.powerint.com. Power Integrations grants its customers a license under certain patent rights as set forth at http://www.powerint.com/ip.htm.
The PI logo, TOPSwitch, TinySwitch, LinkSwitch, DPA-Switch, PeakSwitch, EcoSmart, Clampless, E-Shield,
Filterfuse, PI Expert and PI FACTS are trademarks of Power Integrations, Inc. Other trademarks are property of their respective
companies. ©Copyright 2006, Power Integrations, Inc.
Power Integrations
5245 Hellyer Avenue
San Jose, California 95138
MAIN PHONE NUMBER
+1 408-414-9200
APPLICATIONS HOTLINE
+1 408-414-9660
APPLICATIONS FAX
+1 408-414-9760
For a complete listing of worldwide sales offices,
please visit www.powerint.com
B
7/06
www.powerint.com