DER-110
Dual Output Non-Isolated Power Supply
October 26, 2005
2 Power Supply Specification
Description
Symbol
Min
Typ
Max
Units
Comment
Input
2 Wire – no P.E.
Voltage
Frequency
VIN
fLINE
90
47
265
64
VAC
Hz
50/60
No-load Input Power (230 VAC)
0.7
W
Output
5%
Output Voltage 1
Output Ripple Voltage 1
Output Current 1
VOUT1
VRIPPLE1
IOUT1
5
50
500
V
mV
mA
20 MHz bandwidth
15%
Output Voltage 2
VOUT1
VRIPPLE1
IOUT1
24
V
20 MHz bandwidth
Output Ripple Voltage 2
Output Current 2
200
200
mV
mA
Output Power
POUT
7.3
W
%
Measured at POUT (7.3 W), 25 oC
Efficiency
80
η
Environmental
Meets CISPR22B / EN55022B
Conducted EMI
Designed to meet IEC950, UL1950
Class II
Safety
1.2/50 µs surge, IEC 1000-4-5,
Series Impedance:
Surge
4
kV
Differential Mode: 2 Ω
Common Mode: 12 Ω
100 kHz ring wave, 500 A short
circuit current, differential and
common mode
Surge
3
0
kV
oC
Free convection, sea level
Ambient Temperature
TAMB
70
Power Integrations
Tel: +1 408 414 9200 Fax: +1 408 414 9201
www.powerint.com
Page 4 of 23