Powerex, Inc., 200 Hillis Street,Youngwood, Pennsylvania 15697-1800 (412) 925-7272
BCR5AS
Surface Mount Triac
5 Amperes/400-600 Volts
Electrical and Thermal Characteristics, T = 25 °C unless otherwise specified
j
Characteristics
Symbol
Test Conditions
Min.
–
Typ.
–
Max.
3.0
Units
°C/W
mA
Thermal Resistance, Junction-to-case
R
th(j-c)
DRM
–
Voltage – Blocking State
I
V
= Maximum Allowable
–
–
2.0
DRM
Repetitive Off-state Current
Repetitive Off-state Voltage Rating,
Gate Open Circuited,
T = 125°C
j
Current – Conducting State
Peak On-state Current
V
T = 25°C, 8.3ms Pulsewidth
–
–
–
–
1.8
–
Volts
TM
c
Duty Cycle < 2%, I
= 7A
TM
Critical Rate-of-rise of Commutating
Off-state Voltage (Commutating dv/dt)
▲ for Inductive Load
(dv/dt)
–
V/s
c
(Switching)
Commutating
dv/dt, (dv/dt)
(V/sec)
(Volts) Load Type Minimum Test Condition
Commutating Voltage &
Current Waveform
(Inductive Load)
c
⌬ Part
Number
V
DRM
BCR5AS-8L 400
BCR5AS-12L 600
L
L
5
5
T = 125°C,
j
SUPPLY
VOLTAGE
t
Rate of Decay
On-state
Commutating
Current
(di/dt)
C
MAIN
CURRENT
t
V
V
D
(di/dt) = -2.5A/msec;
MAIN
VOLTAGE
c
t
Peak Off-state
Voltage
(dv/dt)
C
D
V
= 400V
D
T-18