PMCU-XXXXEMI/RFI
COMMON MODE
LINEFILTERS
MEDIUM POWER
Ê Rated Voltage: 250Vac, 45/400Hz
Ë < 50OC Temp Rise & Rated Current
Ì Operating Temp -40 to +80 OC
Í Low Profile Construction
Î 3750Vrms Isolation
Ï Insulation Resistance @ 500Vdc >100MW
(1)
ELECTRICAL SPECIFICATIONS AT 25OC - OPERATING TEMPERATURE RANGE -40OC TO +80OC
LoadVA
@RMSLine
RATED
RMSCurrent
Ampsrms
INDUCTANCE
@ 1KHz
(mHMin.)
DCR
EACH WINDING
(Ohms Max.)
PART
NUMBER
PACKAGE
115V 230V
PMCU-0470
PMCU-0330
PMCU-0220
PMCU-0100
PMCU-0056
PMCU-0033
PMCU-0015
0.35
0.40
0.50
0.65
40.25 80.50
46.00 92.00
57.50 115.00
74.75 149.50
47.0
33.0
22.0
10.0
5.6
2.40
2.00
1.20
0.75
0.40
0.25
0.11
U10.5
U10.5
U10.5
U10.5
U10.5
U10.5
U10.5
1.00 115.00 230.00
1.20 138.00 276.00
1.80 207.00 414.00
3.3
1.5
PMCU-2470
PMCU-2330
PMCU-2220
PMCU-2100
PMCU-2056
PMCU-2033
PMCU-2015
0.50
0.60
0.75
57.50 115.00
69.00 138.00
86.25 172.50
47.0
33.0
22.0
10.0
5.6
1.35
1.00
0.60
0.34
0.15
0.10
0.04
U16
U16
U16
U16
U16
U16
U16
1.00 115.00 230.00
1.40 161.00 322.00
2.00 230.00 460.00
2.70 287.50 575.00
3.3
1.5
Notes:
(1) TemperatureRiseisspecifiedatmaximumcontinuouscurrent.Lowercurrents
willresultinreducedtemperaturerise. Designpointis<50OCriseatratedcurrent.
SCHEMATIC
APPLICATION
DOT ON BOBBIN
DENOTES PIN #1
TYPICAL APPLICATION CIRCUIT
1
4
3
PMCU-XXXX
F1
LINE
2
1
Cy
Cy
L1B
L1A
115/230Vac
50/60Hz
FG
Cx
Cx
3
4
NEUT
Cx = 0.1uF (Line-to-Line)
Cy = 2200pF (Line-to-FG)
2
Specifications subject to change without notice.
pmcu 09/01
20381 BARENTS SEA CIRCLE, LAKE FOREST, CA 92630 · TEL: (949) 452-0511 · FAX: (949) 452-0512 · http://www.premiermag.com
3