PMCU-XXXXEMI/RFI
COMMON MODE
LINEFILTERS
LOW PROFILE-VERT
Ê Rated Voltage: 250Vac, 45/400Hz
Ë < 30OC Temp Rise & Rated Current
Ì Operating Temp -40 to +80 OC
Í Low Profile Vertical Construction
Î 3750Vrms Isolation
Ï Insulation Resistance @ 500Vdc >100MW
(1)
ELECTRICAL SPECIFICATIONS AT 25OC - OPERATING TEMPERATURE RANGE -40OC TO +80OC
LoadVA
@RMSLine
RATED
RMSCurrent
mArms
INDUCTANCE
@ 1KHz
(mHMin.)
DCR
PART
EACH WINDING PACKAGE
(Ohms Max.)
NUMBER
115V 230V
17.25 34.50
23.00 46.00
28.75 57.50
40.25 80.50
51.75 103.50
69.00 138.00
92.00 184.00
115.00 230.00
172.50 345.00
230.00 460.00
345.00 690.00
PMCU-5470
PMCU-5330
PMCU-5220
PMCU-5100
PMCU-5056
PMCU-5033
PMCU-5015
PMCU-5009
PMCU-5005
PMCU-5002
PMCU-5001
Notes:
150
200
250
350
450
600
800
1000
1500
2000
3000
47.0
33.0
22.0
10.0
5.6
3.3
1.5
0.9
0.5
6.90
4.95
3.70
1.40
0.75
0.50
0.30
0.16
0.12
0.06
0.03
U9.8
U9.8
U9.8
U9.8
U9.8
U9.8
U9.8
U9.8
U9.8
U9.8
U9.8
0.2
0.1
(1) TemperatureRiseisspecifiedatmaximumcontinuouscurrent.Lowercurrents
willresultinreducedtemperaturerise. Designpointis<30OCriseatratedcurrent.
SCHEMATIC
DIMENSIONS mm (IN)
PART IS REVERSIBLE.
IT CAN BE INSERTED INTO PCB EITHER WAY.
16.5
(.65)
MAX
11.2
(.441)
MAX
DOT ON BOBBIN
DENOTES PIN #1
CORE
CLAMP
1
4
16.3
(.642)
MAX
L1B
L1A
4.0
(.157)
TYP
Æ
0.6
(.024)
2
3
4
1
7.0
TYPICAL APPLICATION CIRCUIT
(.276)
TOP VIEW
1
2
PMCU-XXXX
F1
3
4
2
1
LINE
2
1
P
PMCU-5XXX
Cy
Cy
M
115/230Vac
50/60Hz
8.0
(.315)
FG
Cx
Cx
3
4
NEUT
Cx = 0.1uF (Line-to-Line)
Cy = 2200pF (Line-to-FG)
4
3
Specifications subject to change without notice.
pmcu 12/98
20381 BARENTS SEA CIRCLE, LAKE FOREST, CA 92630 · TEL: (949) 452-0511 · FAX: (949) 452-0512 · http://www.premiermag.com
2