PSF149 Characteristics
WWW.PHIHONG.COM
ENVIRONMENTAL:
INPUT:
Operation Temperature
AC Input Voltage Rating
0 to 50˚C
Storage Temperature
100 to 240VAC
AC Input Voltage Range
90 to 264VAC
AC Input Frequency
-25˚C to +85˚C
Humidity
20 to 90%
Emissions
47 to 63Hz
Input Surge Current
FCC Class A
EN 55022 Class A
Immunity
60A max.@cold start for 230VAC
Input Current
4A max.
OUTPUT:
Efficiency
70% min.@115VAC and max. load
Hold-up Time
ESD
EN61000-4-2: Level 3
RS
EN61000-4-3: Level 2
FET/Burst EN61000-4-4: Level 2
Surge
EN61000-4-5: (L-G) Level 3
(L-N) Level 2
EN61000-4-6: Level 2
EN61000-4-11
16mS min.@120VAC and max.
CS
DIP
Load
Harmonic EN61000-3-2 Class D
Power Factor Correction
Flicker
EN61000-3-3
>0.9@max. load
Overvoltage Protection
6.8V max. for +5V
Overcurrent Protection
All outputs equipped with short
circuit protection
GENERAL:
Dielectric Withstand (HIPOT) Test
Primary to secondary: 3000VAC 10mA
1 min.@without U-CASE
MTBF (Full load, 25˚C)
50K Hrs min. at max. load
25˚C ambient temperature
Dimension Diagram Unit: mm (inch)
PSF149/0312