PSAC24A Characteristics
INPUT:
WWW.PHIHONG.COM
Immunity
AC Input Voltage Rating
100 to 240V AC
EN 61000-3-2
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
AC Input Voltage Range
90 to 264V AC
AC Input Frequency
50 to 60Hz
Input Current
Dielectric Withstand (Hi-pot) Test
0.6A (RMS) maximum at 100V AC
≥3KVac/10mA @1minute
Leakage Current
FEATURES:
0.25mA max at 100Vac/60Hz & 240Vac/50Hz Over-Voltage Protection
≤20.4V max at 90Vac~264Vac, max load
Inrush Current
40A max at 115VAC/60Hz
80A max at 230VAC/50Hz
(Cold start at ambient 25°C)
Over-Current Protection
≤4A max at 90Vac~264Vac, max load
Short-Circuit Protection
OUTPUT:
Efficiency
DOE Level VI
Units shall be protected against a continuous
short circuit and over current condition over
the operating range. A continuous short circuit
shall not produce excessive heat and no smoke
or fire
Hold-up Time
≥10ms min at 115Vac/60Hz &230Vac/50Hz,
max load
DC Output Connector
2.1 x 5.5mm Center Positive Barrel
ENVIRONMENTAL:
Temperature
Operation
0 to +40°C
Non-operation
Humidity
-20 to +70°C
90%RH max
Emissions
FCC PART 15
Class B
IEC/EN 55022 & CISPR 22 Class B