PSA45 Characteristics
WWW.PHIHONG.COM
AC Input Voltage
Overcurrent Protection
90-264VAC
AC Input Frequency
Short circuit, AutoRestart
Operation Temperature
0 to 50˚C, derated to 50% at 70˚C
Storage Temperature
47 to 63Hz
AC Input Current
-25˚C to +85˚C
1A rms (120VAC)
0.5A rms (240VAC)
MTBF
AC Inrush Current (Cold Start)
Full Load, 25˚C
Greater than 100,000 hours,
(MIL-HDBK-217F)
EMI
20A max., at 120VAC, 45W
40A max., at 240VAC, 45W
Leakage Current
Less than 3.5mA (254VAC)
FCC Class B
EN55022B
Immunity
Efficiency
70% @ 45W 120VAC, 60Hz
Regulation (Line)
V1 +2%; V2-4 +2%
Regulation (Load or Cross)
V1 +2%; V2-4 +5%
(Measured output at 20%-100%
load; other outputs at 60% of
load)
Hold-up Time
12msec. 45W load, 120VAC
Switching Frequency
50KHz, typical
Overvoltage Protection
EN 50082-1: 1997
61000-4-2, Level 3
61000-4-3, Level 2
61000-4-4, Level 2
61000-4-5, Level 3
61000-4-6, Level 2
61000-4-11
Mating Connectors
AC: Molex 09-50-3031
DC: Molex 09-50-3061
or 3081 (Quad only)
Crowbar, V1 only;
Dimension Diagram Unit: mm (inch)
For Single Output:
CN1
1
2
1
2
3
4
5
6
L
N
CN2
+V
+V
+V
GND
GND
GND
For Multiple Outputs:
CN1
1
2
1
2
3
4
5
6
7
8
L
N
CN2
V
V
V
GND
GND
V
V
V
2
1
1
3
4
4
GND
PSA45/0403