PSA15R Characteristics
WWW.PHIHONG.COM
Over Voltage Protection
By Zener Clamping
INPUT:
AC Input Voltage Rating
100 to 240VAC
Short Circuit Protection
Output can be shorted without damage
AC Input Voltage Range
90 to 264VAC
ENVIRONMENTAL:
Temperature
Input Current
0.5A(RMS) max. @ 120VAC
0.25A(RMS) max. @ 240VAC
Operation
0 to +40°C
Non-operation
-25 to +75°C
Leakage Current
0.25mA max. @ all line conditions
Humidity
Operation
20 to 90%
Inrush Current (cold)
Emissions
< 30A for 120VAC at max. load
< 60A for 240VAC at max. load
(Cold start @ ambient 25°C)
FCC Class B
CISPR 22 Class B
Dielectric Withstand (Hi-pot) Test
Primary to Secondary: 3000VAC
Input Power Saving
0.5W maximum at no load (except 5V and 6V models)
0.75W maximum at no load (for 5V and 6V models)
DC Output Connector
2.1x5.5mm Center Positive Standard
OUTPUT:
Efficiency
Mating Connector
≥ 74.4% average efficiency (except 5V and 6V models)
≥ 74.4% average efficiency at 115VAC, ≥ 73.4%
average efficiency at 230VAC (for 5Vand 6V models)
Kycon KLD-0202-A or equivalent
AC Input Clips (sold separately)
US: RPA
Europe: RPE
UK: RPK
Hold-up Time
10mS min. @ 120VAC and max. load
Australia: RPS
Over Current Protection
Output equipped with short circuit protection – auto
restart
Dimension Diagram Unit: mm (inch)