PSA10R Characteristics
Emissions
INPUT:
FCC Class B
EN 55022 B
Immunity
AC Input Voltage
90 to 264 VAC
AC Input Frequency
EN 50082-1: 1997
61000-4-2, Level 3
61000-4-3, Level 2
61000-4-4, Level 2
61000-4-5, Level 3
61000-4-6, Level 3
61000-4-11
47 to 63Hz
AC Input Current
0.5Arms (120VAC)
0.25Arms (240VAC)
AC Inrush Current (Cold)
30A max. (120VAC)
60A max. (240VAC)
Efficiency
65% minimum
OUTPUT:
Hold-up Time
16ms Full load, 115VAC
Overvoltage Protection
>120%
Overcurrent Protection
>120%, Auto Restart
ENVIRONMENTAL:
Operation Temperature
(Convection)
0 to 35°C
Storage Temperature
(Convection)
-25 to +85°C
Humidity
10 to 90% RH (Non-condensing)
GENERAL:
Leakage Current
<0.25mA (254VAC)
Dielectric Withstand (Hipot)
Input to Output
3000VAC, 1 min., 10mA
Switching Frequency
100KHz (typical)
MTBF (Full Load, 25°C)
150K Hrs.
MIL-HDBK-217F
Power On Indicator
Green LED
AC Input Plugs
(Order Separately)
USA: RPA
Europe: RPE
UK:RPK
Australia:RPS
DC Output Cord/Connector
1.8meter
2.1mm x 5.5mm x 10mm Coaxial
Plug; Center Positive Standard
www.phihong.com
PSA10R/0205