POE90U-1BT Characteristics
INPUT:
WWW.PHIHONG.COM
Isolation Test
AC Input Voltage Range
90 to 264VAC
Primary to Secondary:
4242VDC for 1 minute 10mA
Primary to Field Ground:
2121VDC for 1 minute
AC Input Voltage Rating
100 to 240VAC, 47-63Hz
Immunity
AC Input Current
2.5A (RMS) maximum for 90VAC
1.2A (RMS) maximum for 240VAC
ESD:
RS:
EFT:
Surge:
CS:
IEC61000-4-2 Level 3
IEC61000-4-3 Level 3
IEC61000-4-4 Level 2
IEC61000-4-5 Level 3
IEC61000-4-6 Level 2
Leakage Current
3.5mA maximum @ 264VAC 50Hz
Voltage Dips IEC61000-4-11
Harmonic:
IEC61000-3-2 Class A
AC Inrush Current
50A (RMS) maximum for 115VAC
75A (RMS) maximum for 230VAC
Insulation Resistance
Primary to Secondary: >10M OHM 500VDC
Primary to Field Ground: >10M OHM
500VDC
OUTPUT:
Total Output Power
90W
FEATURES:
Over Current Protection
Output #1(OUT) <1000mA
Output #2(OUT) <1000mA
Output #1 and #2 combined(OUT) <2000mA
Ripple and Regulation
250mV max @25C, 100-240VAC
Efficiency
75% (typical) at maximum load, and 120VAC
60Hz
Over Voltage Protection
Meets UL requirements
Hold-up Time
10mS min. 120VAC 60Hz max load
Short Circuit Protection
The output can be shorted permanently
without damage
ENVIRONMENTAL:
Temperature
LED Indicators
Operation
Non-operation
Humidity
-20°C to +40°C
-20°C to +65°C
5 to 90%
No LED - Power failure
Green LED short Blinking - POE power ready
but no connection
Green LED solid - POE output power good
Green/Red LED alternate short blinking - POE
detection failure
EMC
FCC Part 15 Class B
EN55022/EN55032 Class B
Green LED short/Red long blinking - POE
output over power or short
Input Connector
Output Connection
IEC320 inlet 3 pin
+pins 3,6,4,5 / -pins 1,2,7,8
Revision 2/7/2018