POE60U Characteristics
WWW.PHIHONG.COM
INPUT:
AC Input Voltage Range
90 to 264VAC
EMC
FCC Part 15 Class B
EN55022 Class B
AC Input Voltage Rating
100 to 240VAC,47-63Hz
Isolation Test
Primary to Secondary: 3000VAC for 1 minute 10mA
Primary to F.G.: 1500VAC for 1 minute
Output to F.G.: 1500VAC
AC Input Current
1A(RMS) max. for 90VAC
0.7A(RMS) max. for 240VAC
Immunity
ESD:
EN61000-4-2. Level 3
EN61000-4-3. Level 2
EN61000-4-4. Level 2
EN61000-4-5. Level 3
EN61000-4-6. Level 2
EN61000-4-11
Leakage Current
0.25mA max. @ 254VAC 60Hz
RS:
EFT:
Surge:
CS:
Voltage Dips
Harmonic:
AC Inrush Current
15A(RMS) max. for 115VAC
20A(RMS) max. for 230VAC
EN61000-3-2
OUTPUT:
Total Output Power
60W
Insulation Resistance
Primary to secondary: >10M OHM 500VDC
Primary to FC: >10M OHM 500VDC
DC Offset
FEATURES:
Detection
No Data degradation with DC imbalance 18mA per min.
Same as IEEE802.3af except 12.5kohm detection
resistor value required at Powered device.
Efficiency
65% (typical) at Max. load, and 120VAC 60Hz
Over Voltage/Current, Short Circuit Protection
Outputs equipped with short circuit protection and overload
protection as per 802.3af specification except max average
current is 0.55A, Peak 0.6A per pair
Hold-up Time
16mS min. 120VAC and max. load
Transient O/P Voltage Protection
60V max.
The output can be shorted permanently without damage
Indicators
ENVIRONMENTAL:
Temperature
Led #1 indicator for input power “on” GREEN
Led #2 Indicator for fault-RED
Led #3 Indicator that Detected and Connected to valid
IEEE802.3af load-GREEN
Operation
0 to +40°C
Non-operation
-25 to +65°C
Humidity
Operation
Input Connector
IEC320 inlet 3 pin
5 to 90%
Dimension Diagram Unit: mm (inch)