PDA12X-350C Characteristics
INPUT:
Immunity
EN61000-4-2
EN61000-4-5**
EN61000-3-2
AC Input Voltage
185 to 304VAC for A Models
100 to 136VAC for B Models
Class C
**In order to meet 2.5KV Ring Wave per Energy Star
SSL1.1 external MOVs are required:
Input Frequency
47~63Hz
Leakage Current
<0.5mA at 230VAC and maximum load
560V 10mm for A models
240V 10mm for B models
Maximum Input Current
≤1A
OUTPUT:
Total Output Power
12W
Efficiency
75% for A models
77% for B models
Isolation Test
Primary to Secondary: 3000VAC, <5.5mA, 1 minute
Power Factor
≥0.9
Insulation Resistance
Primary to Secondary: 500VDC, >5M ohm, 1 minute
Ripple
Shall be less than 5% (p-p) of setting DC current output
under electrical load condition
Input Over-Current Protection
The input power line will be fused with a 2A fuse
ENVIRONMENTAL:
Operating Temperature
-40 to 60°C (10W)
-40 to 50°C (12W)
-40 to 77°C
Short Circuit Protection
May withstand short circuit across outputs without
damage
Storage Temperature
Operating Humidity
Storage Humidity
10 to 95%
5 to 95%
Design Life
50K Hours minimum at max load and ambient 50°C
Case Temperature
+80°C
Design Life (H Models)
100K Hours minimum at max load and ambient 50°C
Warranty
3 Years for standard models
8 Years for high reliability (-H) models
Input Connection
ANYTEK 2-pin terminal block – p/n
HC0200C3001AG
Ingression Protection
IP20; plastic housing
Terminal
Position
Specification
Color
Black
White
Line
Neutral
AWG18~22 Solid or Standard
AWG18~22 Solid or Standard
Mounting Provision
Screw mounting, accessible without opening unit
DC Output Connection
Superior Tech 2-pin p/n WRDD-DSXXT20WAA
mating AMP Connector p/n 1496992-1 or equivalent
Open Circuit Protection
Once the circuit is opened, the output voltage should be
less than 45V at normal AC input conditions
EMC
FCC 47 part 15/18 Class A
EN55015/CISPR 15