Trigge re d Spa rk Ga p Ra tings
Typic a l De la y Tim e *
* whe n ope ra te d in m ode A
(Na nos e c onds )
O -A
V
T
Sim ulta ne ous Ra tings Sim ulta ne ous Ra tings
Pe rkinElm e r Ra nge , kV
Min Trig
(kV Ope n
Circ uit
Re c om m e nde d
Pe rkinElm e r
Tra ns form e r
Crowba r Se rvic e ,
Typic a l Life :
Re pe titive Switc hing
Typic a l Life :
Mode l
No.
Min/Ma x
(1 ,1 0 )
Trigge r
Mode
SBV, kV
(4 )
At 7 0 % SBV At 4 0 % SBV
5 0 0 0 -2 0 ,0 0 0 Shots
1 -5 Million Shots
(2 )
0.7
1.3
4.4
8
(3 )
(5 )
(6 , 7 )
(1 1 )
(1 1 )
GP-89
GP-90
2.1
3.4
10
20
1.6
6
2.6
4.2
C
C
TR-148A
5 kA peak
3 millicoulombs/shot
lb = 35 mAdc
lp = 6 Aac
10
100
1000
GP-91
12.5
25
A,C
A, C
A,B
0.1 coulomb
TR-180B
TR-148A
TR-180B
GP-93
GP-82B
GP-31B
GP-20B
GP-46B
GP-85
0.4
2
2
7.5
7.5 kA peak
0.2 coulomb
4 millicoulombs/shot
lb = 60 mAdc
lp = 8 Aac
10
20
30
30
300
300
A
3.5
8
11
20
6
14
25
2
8
A,B
A
TR-1795
TR-180B
TR1700
GP-86
6
15
24
36
6
20
25 kA peak
0.4 coulomb
4 millicoulombs/shot
lb = 100 mAdc
lp = 10 Aac
GP-87
10
12
2
30
GP-70
42(8)
7.5
GP-30B
GP-22B
GP-12B
GP-14B
GP-41B
GP-32B
GP-15B
GP-74B
GP-81B
A,B
A
6
15
24
36
36
48
60
100
100
19
50 kA peak
0.5 coulomb
TR-1795
TR-1700
20
30
300
10
12
12
20
25
40
40
30
42(8)
42
10 millicoulombs/shot
Peak currents up to 100 lb = 200 mAdc
A,B
A
TR-1795
TR-1700
kA and charge transfer
20
20
30
30
300
300
60(8)
86(8)
120(8)
120(9)
lp = 15 Aac
up to 5 coulombs are
obtainable at reduced
life (100-1000 shots).
TR-1795
TR-1700
A
Note s
1. Optimum operating voltage is typically 60 to 80% of SBV.
2. Operation below minimum value may result in erratic firing
over time.
8. These units must be operated in a liquid or gas dielectric to prevent
external flashover: GP-70 and GP-14B, above 24 kV; GP-32B and
GP-15B, above 35 kV; GP-74B and GP-81B, above 60 kV.
9. Designed for high altitude, high holdoff conditions.
3. Operation at this value may result in self-firing over time.
4. Represents minimum main-gap breakdown voltage with no
trigger applied.
10. Other voltage ranges and mechanical configurations are available
on request; for example, the GP-20B can be supplied with a 6 to
16 kV operating range by specifying GP-20B-20. The 20 would be
the SBV and E-E maximum would be 80% of SBV = 16kV.
5. Value shown contains safety factor for end-of-life requirements.
6. PerkinElmer TM-11A Trigger Module can be used to trigger
all gaps.
2
1
11. E = Stored energy in joules ( / CV ), lb = average current in
2
7. Transformers listed vary mechanically and electrically. See
PerkinElmer Transformer Data Sheet.
amperes, lp = RMS current in amperes, R = total circuit resistance
in ohms, P = average power in watts.
p a g e 2
P e r k in E lm e r Op to e le c tro nic s