AME270461 Series  
AME270461 Block Diagram  
1
2
3
12  
Input  
Output  
11  
10  
20 nF  
2.24 µF  
1.12 µF  
Case  
9
4
5
6
20 nF  
8
Input  
Return  
Output  
Return  
7
Refer to last page for Pin Designation  
Circuit Operation and Application Information  
Employing only passive elements, AME filter  
operation is initiated simply by insertion into the input  
power path between one or more DC/DC converters  
and their input DC voltage bus. In this connection,  
output pins of the filter will be connected to input  
pins of the converters. When a single AME filter is  
used in conjunction with multiple DC/DC converters,  
the use will be limited to the maximum output current  
The AME series of filters employ three stages of  
filtering in a low pass configuration designed to  
attenuate the higher frequency components of ripple  
currents generated by high frequency switching DC/  
DC converters. The Block Diagram describes the  
general arrangement of the principal elements which  
have been connected to provide both differential and  
normal mode buffering between the input and output  
terminals.  
capability specified in the AME electrical table.1  
A
typical connection utilizing one filter to drive two  
converters is illustrated on page 1.  
1
To calculate the input current (i ) requirement of any one converter, first determine the maximum output power by  
in  
multiplying output voltage by maximum load current, divide this power by the efficiency to obtain input power and then divide  
input power by inputvoltage to obtain the input current (i ). Note that to obtain worst case input current, you must use  
in  
maximum load current, minimum efficiency and minimum line voltage in this calculation.  