欢迎访问ic37.com |
会员登录 免费注册
发布采购

RS2259PG 参数 Datasheet PDF下载

RS2259PG图片预览
型号: RS2259PG
PDF下载: 下载PDF文件 查看货源
内容描述: Secondâ ????端调节电流模式PWM功率切换器 [Second‐Side Regulation Current Mode PWM Power Switcher]
分类和应用:
文件页数/大小: 9 页 / 427 K
品牌: ORISTER [ ORISTER CORPORATION ]
 浏览型号RS2259PG的Datasheet PDF文件第1页浏览型号RS2259PG的Datasheet PDF文件第2页浏览型号RS2259PG的Datasheet PDF文件第3页浏览型号RS2259PG的Datasheet PDF文件第4页浏览型号RS2259PG的Datasheet PDF文件第5页浏览型号RS2259PG的Datasheet PDF文件第7页浏览型号RS2259PG的Datasheet PDF文件第8页浏览型号RS2259PG的Datasheet PDF文件第9页  
Page No. : 6/9
Internal synchronized Slope Compensation 
Built‐in slope compensation circuit adds voltage ramp onto the current sense input voltage for PWM generation. 
This greatly improves the close loop stability at CCM and prevents the sub‐harmonic oscillation and thus reduces 
the output ripple voltage. 
 
Drive 
The internal power MOSFET in RS2259 is driven by a dedicated gate driver for power switch control. Too weak the 
gate driving strength results in higher conduction and switch loss of MOSFET while too strong gate drive results 
the compromise of EMI. 
 
A good tradeoff is achieved through the built‐in totem pole gate design with right output strength and dead time 
control. The low idle loss and good EMI system design is easier to achieve with this dedicated control scheme. 
 
In addition to the gate drive control scheme mentioned, the gate drive strength can also be adjusted externally by 
a resistor connected between V
DD
 and V
DDG
, the falling edge of the Drain output can be well controlled. It provides 
great flexibility for system EMI design. 
 
Protection Controls 
Good power supply system reliability is achieved with its rich protection features including Cycle‐by‐Cycle current 
limiting (OCP), Over Load Protection (OLP) and over voltage clamp, Under Voltage Lockout on VDD (UVLO). 
 
With Orister Proprietary technology, the OCP is line voltage compensated to achieve constant output power limit 
over the universal input voltage range. 
 
At  overload  condition  when  FB  input  voltage  exceeds  power  limit  threshold  value  for  more  than  T
D_PL
,  control 
circuit reacts to shut down the switcher. Switcher restarts when V
DD
 voltage drops below UVLO limit. 
 
V
DD
 is supplied by transformer auxiliary winding output. It is clamped when V
DD
 is higher than 30V. The output of 
RS2259  is  shut  down  when  V
DD
 
drops  below  UVLO(ON)  limit  and  Switcher  enters  power  on  start‐up  sequence 
thereafter. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
DS‐RS2259‐
     
May, 2010 
www.Orister.com