Page No. : 3/9
Block Diagram
Absolute Maximum Ratings
Parameter
Drain Voltage (off state)
VDD Voltage
VDDG Input Voltage
VDD Clamp Continuous Current
FB Input Voltage
Sense Input Voltage
Operating Ambient Temperature
Storage Temperature
Lead Temperature (soldering, 10sec)
ESD Voltage Protection, Human Body Model
ESD Voltage Protection, Machine Model
Symbol
V
DRAIN
V
DD
V
DDG_IN
I
VDD_CLAMP
V
FB_IN
V
SENSE_IN
T
OPR
T
STG
‐
‐
‐
Ratings
‐0.3 to 650
‐0.3 to 30
‐03 to 30
10
‐0.3 to 7
‐0.3 to 7
‐40 to +85
‐55 to +150
+260
2
200
Units
V
V
V
mA
V
V
o
C
o
C
o
C
KV
V
NOTE:
1.
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings
only, and function operation of the device at these or any other conditions beyond those indicated under “recommended operating
conditions” is not implied. Exposure to absolute‐maximum–rated conditions for extended periods may affect device reliability.
2.
Caution: Stress above the listed absolute maximum rating may cause permanent damage to the device. * HBM B: 2000V to 3999V
Output Power Table
DIP‐8 Package
230VAC ±15%
Open Frame
(Note)
28W
85 to 265VAC
Open Frame
(Note)
24W
Notes: Maximum practical continuous power in an open frame design with sufficient drain pattern as a heat sink, at 50
o
C ambient.
DS‐RS2259‐
May, 2010
www.Orister.com