Page No. : 8/8
Table 4 Line Regulation & Load Regulation
Input voltage
90Vac/60HZ
115Vac/60HZ
230Vac/50HZ
264Vac/50HZ
No load
10.3mV
12.5mV
17.6mV
19.4mV
Full load
23.4mV
24.2mV
26.8mV
29.0mV
<60mV
Specification
Test result
Pass
Pass
Pass
Pass
Note
Note: Ripple & noise was measured at DC cord end(1.2M/18AWG)with a 0.1uF/100V ceramic cap connected in parallel
with a 10uf/50V electrolytic cap. Bandwidth was limited to 200MHz.
Table 5
Test Item
Input characteristic
Input current
Standby power
Efficiency
Output characteristic
Line regulation
Load regulation
Ripple & Noise
Over shoot & Under shoot
Dynamic test
Time sequence
Turn on delay time
Hold up time
Rise time
Fall time
Protection
Over voltage protection
Over current protection
Short circuit protection
5. Brownout/Brownout recovery
Pass
1.2~1.7A
Pass
Pass
<1S
>10mS
300mS(max)
12.4mS
14.6 mS
11.7 mS
1%
5%
60mV
600mV
600mV
0.008%
0.033%
29mV(max)
350mV
300mV
(264Vac,with LED (4mA current))
0.3A Max.
<0.3W
>75%
0.163A
0.27W
81.9%(min)
Specification
Test result
DS-RS2201-01
Nov, 2007
www.Orister.com