欢迎访问ic37.com |
会员登录 免费注册
发布采购

OP240 参数 Datasheet PDF下载

OP240图片预览
型号: OP240
PDF下载: 下载PDF文件 查看货源
内容描述: 塑料红外发光二极管 [Plastic Infrared Emitting Diode]
分类和应用: 二极管
文件页数/大小: 3 页 / 230 K
品牌: OPTEK [ OPTEK TECHNOLOGIES ]
 浏览型号OP240的Datasheet PDF文件第1页浏览型号OP240的Datasheet PDF文件第3页  
Plastic Infrared Emitting Diode
OP240 Series
OP245 Series
OP245 (A, B, C, D)
1
Pin #
1
2
2
LED
Cathode
Anode
CONTAINS POLYSULFONE
To avoid stress cracking, we suggest using
ND Industries’
Vibra-Tite
for thread-locking.
Vibra-Tite
evaporates fast without causing structural
failure in OPTEK'S molded plastics.
DIMENSIONS ARE IN:
[MILLIMETERS]
INCHES
Absolute Maximum Ratings
(T
A
=25°C unless otherwise noted)
Storage and Operating Temperature Range
Reverse Voltage
Continuous Forward Current
Peak Forward Current
Lead Soldering Temperature [1/16 inch (1.6 mm) from case for 5 seconds with soldering iron]
Power Dissipation
-40
o
C to +100
o
C
2.0 V
50 mA
3.0 A
260° C
(1)
100 mW
(2)
Electrical Characteristics
(T
A
= 25°C unless otherwise noted)
SYMBOL
Input Diode
Apertured Radiant Incidence
OP240A, OP245A
OP240B, OP245B
OP240C, OP245C
OP240D, OP245D
Forward Voltage
Reverse Current
Wavelength at Peak Emission
Spectral Bandwidth between Half Power
Points
Spectral Shift with Temperature
Emission Angle at Half Power Points
Output Rise Time
Output Fall Time
0.60
0.40
0.20
0.05
-
-
-
-
-
-
-
-
-
-
-
-
-
-
890
80
±0.18
40
500
250
-
1.20
0.86
-
1.80
100
-
-
-
-
-
-
PARAMETER
MIN
TYP
MAX
UNITS
TEST CONDITIONS
E
E (APT)
mW/cm
2
I
F
= 20 mA
(3)
V
F
I
R
λ
P
B
∆λ
P
/∆T
θ
HP
t
r
t
f
V
µA
nm
nm
nm/°C
I
F
= 20 mA
V
R
= 2.0 V
I
F
= 10 mA
I
F
= 10 mA
I
F
= Constant
Degree I
F
= 20 mA
ns
ns
I
F(PK)
=100 mA, PW=10 µs, and
D.C.=10.0%
Notes:
1. RMA flux is recommended. Duration can be extended to 10 seconds maximum when flow soldering. A maximum of 20 grams force
may be applied to the leads when soldering.
2. Derate linearly 1.33 mW/° C above 25° C.
3. E
E(APT)
is a measurement of the average apertured radiant energy incident upon a sensing area 0.180” (4.57 mm) in diameter
perpendicular to and centered on the mechanical axis of the lens and 0.653” (6.60 mm) from the lens tip. E
E(APT)
is not necessarily
uniform within the measured area.
OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
Issue A.1
01/07
Page 2 of 3
OPTEK Technology Inc. —
1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747
FAX: (972) 323-2396 sensors@optekinc.com www.optekinc.com