1N4001, 1N4002, 1N4003, 1N4004, 1N4005, 1N4006, 1N4007
MAXIMUM RATINGS
Rating
Symbol 1N4001 1N4002 1N4003 1N4004 1N4005 1N4006 1N4007 Unit
†Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage
V
V
V
50
100
200
400
600
800
1000
V
RRM
RWM
R
†Non−Repetitive Peak Reverse Voltage
(halfwave, single phase, 60 Hz)
V
60
35
120
70
240
140
480
720
420
1000
560
1200
700
V
RSM
†RMS Reverse Voltage
V
280
1.0
V
A
R(RMS)
†Average Rectified Forward Current
(single phase, resistive load,
I
O
60 Hz, T = 75°C)
A
†Non−Repetitive Peak Surge Current
(surge applied at rated load conditions)
I
30 (for 1 cycle)
−65 to +175
A
FSM
Operating and Storage Junction
Temperature Range
T
J
°C
T
stg
Maximum ratings are those values beyond which device damage can occur. Maximum ratings applied to the device are individual stress limit
values (not normal operating conditions) and are not valid simultaneously. If these limits are exceeded, device functional operation is not implied,
damage may occur and reliability may be affected.
ELECTRICAL CHARACTERISTICS†
Rating
Symbol
Typ
0.93
−
Max
1.1
Unit
V
Maximum Instantaneous Forward Voltage Drop, (i = 1.0 Amp, T = 25°C)
v
F
J
F
Maximum Full−Cycle Average Forward Voltage Drop, (I = 1.0 Amp, T = 75°C, 1 inch leads)
V
F(AV)
0.8
V
O
L
Maximum Reverse Current (rated DC voltage)
I
R
mA
(T = 25°C)
(T = 100°C)
J
0.05
1.0
10
50
J
Maximum Full−Cycle Average Reverse Current, (I = 1.0 Amp, T = 75°C, 1 inch leads)
I
R(AV)
−
30
mA
O
L
†Indicates JEDEC Registered Data
http://onsemi.com