Industrial Version
PLCC DC Electrical Characteristics (Note 8)
V
EE = −4.2V to −5.7V, VCC = VCCA = GND, TC = −40°C to +85°C
T
C = −40°C
TC = 0°C to +85°C
Symbol
Parameter
Units
Conditions
Loading with
Min
Max
−870
Min
Max
−870
VOH
VOL
Output HIGH Voltage
Output LOW Voltage
Output HIGH Voltage
Output LOW Voltage
Output Reference Voltage
Input Voltage Differential
Common Mode Voltage
Single-Ended
−1085
−1830
−1095
−1025
−1830
−1035
mV
mV
mV
mV
mV
mV
V
V
IN = VIH (Max)
or VIL (Min)
IN = VIH
or VIL (Min)
VBB = −250 µA
−1575
−1620
50Ω to −2.0V
Loading with
50Ω to −2.0V
VOHC
VOLC
VBB
V
−1565
−1255
−1610
−1260
−1395
150
−1380
I
VDIFF
VCM
VIH
150
Required for Full Output Swing
V
CC − 2.0
VCC − 0.5 VCC − 2.0
VCC − 0.5
Guaranteed HIGH Signal for All
Inputs (with one input tied to VBB
VBB (Max) + VDIFF
Input HIGH Voltage
−1115
−870
−1535
240
−1110
−870
mV
mV
)
VIL
Single-Ended
Guaranteed LOW Signal for All
Inputs (with one input tied to VBB
VBB (Min) − VDIFF
Input LOW Voltage
−1830
−1830
−1530
)
IIL
Input LOW Current
Input HIGH Current
0.50
0.50
µA
µA
VIN = VIL (Min)
IIH
240
V
IN = VIH (Max), Da–De = VBB,
Da–De = VIL (Min)
IN = VEE, Da–De = VBB
Da–De = VIL (Min)
Da–De = VBB, Da–De = VIL (Min)
ICBO
Input Leakage Current
−10
−60
−10
−60
µA
V
IEE
Power Supply Current
−30
−30
mA
Note 8: The specified limits represent the “worst case” value for the parameter. Since these values normally occur at the temperature extremes, additional
noise immunity and guardbanding can be achieved by decreasing the allowable system operating ranges. Conditions for testing shown in the tables are cho-
sen to guarantee operation under “worst case” conditions.
PLCC AC Electrical Characteristics
V
EE = −4.2V to −5.7V, VCC = VCCA = GND
Symbol Parameter
fMAXFS Toggle Frequency
T
C = −40°C
T
C = +25°C
TC = +85°C
Units
Conditions
Min
Max
Min
Max
Min
Max
250
250
250
MHz
(Note 9)
(Full Swing)
fMAXRS
Toggle Frequency
(Reduced Swing)
Propagation Delay
Data to Output
700
0.65
0.20
700
0.65
0.35
700
0.70
0.35
MHz
ns
(Note 10)
tPLH
tPHL
tTLH
tTHL
1.70
1.40
1.80
1.10
1.80
1.10
Figures 1, 2
Transition Time
ns
20% to 80%, 80% to 20%
Note 9: Maximum toggle frequency at which VOH and VOL DC specifications are maintained.
Note 10: Maximum toggle frequency at which outputs maintain 150 mV swing.
www.fairchildsemi.com
4