MR27V1652D
ABSOLUTE MAXIMUM RATINGS
Symbol
Parameter
Condition
-
Value
0 to 70
Unit
°C
°C
V
Operating temperature under bias
Storage temperature
Topr
Tstg
VI
-55 to 125
-0.5 to VCC + 0.5
-0.5 to VCC + 0.5
-0.5 to 5
Input voltage
VO
V
Output voltage
relative to VSS
VCC
VPP
PD
V
Power supply voltage
Program power supply voltage
Power dissipation per package
-0.5 to 11.5
1.0
V
-
W
RECOMMENDED OPERATING CONDITIONS FOR READ
(Ta=0 to 70°C)
Parameter
VCC power supply voltage
VPP power supply voltage
Input "H" level
Symbol
VCC
VPP
Condition
Min.
3.0
Typ.
Max.
3.6
Unit
V
-
-
-
-
VCC+0.5
VCC+0.5*
0.6
-0.5
2.2
V
VCC=3.0V-3.6V
VIH
V
VIL
V
Input "L" level
-0.5**
Voltage is relative to Vss
* : Vcc+1.5V (Max.) when pulse width of overshoot is less than 10nS.
** : -1.5V (Min.) when pulse width of undershoot is less than 10nS.
4/10